75
Exchange of SDCS-CON-4
Exchange of SDCS-CON-4
General
All DCS800 size D1 to D7 are equipped with the same controller board SDCS-
CON-4, thus the exchange of the board is similar for all module sizes.
Required Tools
Special tools or material needed in addition to standard tools for the exchange of
the SDCS-CON-4:
Torx screwdrivers: TX10, TX20, TX25
Overview SDCS-CON-4 exchange
1. Save parameters,
2. Write down type code of the drive,
3. Set jumpers on the new SDCS-CON-4 according to the old SDCS-CON-4,
4. Exchange the SDCS-CON-4,
5. Set type code of the drive,
6. Enable application program and
7. Download and compare parameters.