Introduction 
3ADW000195R0501 DCS800 Service Manual e e
 
Type code 
  The type code contains information on the specifications and configuration of the 
drive. The first digits from left express the basic configuration (e.g. DCS800-S01-
2005). The optional selections are given thereafter, on the name plate by plus 
code. The main selections are described below. Not all selections are available for 
all types. 
 
Type code  D C S 8 0 0 -AAX-YYYY-ZZ-  plus code 
Position        A X   Y    Z B  
 
Position    Plus code   
  Product series   DCS800  
A  Type    S0 = Standard converter module IP00  
R0 = Rebuild system 
E0 = Panel solution 
A0 = Enclosed converter 
X  Bridge type    1 = Single bridge (2-Q) 
2 = 2 anti parallel bridges (4-Q) 
Y  Rated DC current    YYYY = Rated current (e.g. 0025 = 25 ADC) 
ZZ  Rated AC voltage    04 = 400 VAC 
05 = 525 VAC 
06 = 600 VAC 
07 = 690 VAC 
08 = 800 VAC 
10 = 990 VAC 
12 = 1200 VAC 
B  Power connection    -  = Standard D1 ... D6 
L = Left side D7 
R = Right side D7 
a = Second thyristor type D5, D6 
  Internal field exciter 
configuration 
+S164 
+0S163 
With internal field exciter, external supply (only D5:25 A, Rebuild kit: 25 A/16 A) 
Without internal field exciter (only D1 ... D4) 
  Fan voltage   
 
+S171 
 
 
 
+S172 
Size D4 
Standard fan voltage:  230 V / 1-ph 
Additional fan voltage:  115 V / 1-ph 
Size D6 
Standard fan voltage for 400 V / 500 V / 800 V units:  400-500 V / 3-ph 
Standard fan voltage for 600 V / 690 V units:    525-690 V / 3-ph 
Additional fan voltage for 600-690 V units:    400-500 V / 3-ph 
  Current measurement  +S175  SDCS-CMA-2 for sizes D5 to D7 
  Voltage measurement  +S186 
+S180 
+S181 
+S182 
+S183 
+S189 
120 V SDCS-SUB-4 for sizes D1 ... D4 
600 V for sizes D6 and D7 
690 V for sizes D6 and D7 
800 V for sizes D6 and D7. 
990 V for sizes D6 and D7. 
Galvanic isolation for sizes D6 and D7 
  SDCS-DSL-4  +S199 
+0S199 
With SDCS-DSL-4 
Without SDCS-DSL-4 
+ plug-in options 
  DCS Control Panel 
 
0J400 
J409 
Without DCS Control Panel 
Door mounting Kit (cable length 3 m) 
  Fieldbus 
 
K454 
K451 
K466 
K458 
Profibus RPBA 
DeviceNet RDNA 
Ethernet IP + Modbus TCP RETA 
Modbus RMBA 
  I/O and DDCS  L500 
L501 
L508 
L509 
Analogue Extension RAIO 
Digital Extension RDIO 
DDCS Communication board (10 Mbaud CH0) SDCS-COM-81 
DDCS Communication board (5 Mbaud CH0) SDCS-COM-82