Fault Tracing Thyristors
3ADW000195R0501 DCS800 Service Manual e e
3ADW000195R0501 DCS800 Service Manual e e
Fault Tracing Thyristors
Tools
For commissioning and fault tracing
Following software tools are mandatory:
DriveWindow Light including commissioning wizard and DWL AP for Adaptive
Program and
DriveWindow for fast drive monitoring using SDCS-COM-8.
Following tools are mandatory in addition to standard tools:
An oscilloscope including memory function with either galvanically isolating
transformer or isolating amplifier (probe) for safe measurements. It can also be
a hand held (portable) oscilloscope.
A clamp on current probe. In case the scaling of the DC load current needs to
be checked it must be a DC clamp on current probe.
A voltmeter (at least CAT III 1000 V):
1000 V probes and test leads:
An ESD-field service kit (ABB Service
Finland code 0001ESD / MS-Antistatic):
Make sure that all equipment in use is suitable for the voltage level applied to the
power part!