Exchange of Thyristors for Size D1 to D4
3ADW000195R0501 DCS800 Service Manual e e
8. Remove the SDCS-PIN-4 board:
OnBoard field exciter
bridge module
Snubber resistor
Thyristor modules
Current transformer Temperature sensor
Remove SDCS-PIN-4
9. Remove the gate leads from the faulty thyristor module and mark the
connectors clearly.
10. Remove the busbars necessary to get full access to the faulty thyristor module.
11. If a current transformer must be removed, mark its position and the
connections clearly.
Note:
Remove only as many parts as needed around the faulty thyristor module.
12. Remove the faulty thyristor module and mark it clearly as defective.