Main order number
Electromagnetic Flowmeter FSM4000
SE41F
-
XXX X X X X X X X X X X X X X XXX XXX
Certificates
PED St
andard
A
Material certificate 3.1 acc. EN 10204 with pressure test acc. AD2000
D
14)
Pressure test acc. AD2000
G
Inspection certificate 3.1 acc. EN 10204
F
Calibration Certificates
Standard
A
Finger
print saved at factory
F
15)
Schutzart / Kabelzuführung
IP 67 / Thread for screw
-type conduit fitting M20 x 1.5
2
IP 67
/ Thread for screw-type conduit fitting NPT 1/2 in
4
IP 68
/ Thread for screw-type conduit fitting M20 x 1.5
7
16)
IP 68 / Cable connected and connection box potted
8
IP 68
/ Cable connected and connection box potted NPT 1/2 in
A
Design
Without pre-amplifier
1
17)
With pre
-amplifier type A
2
18)
With pre
-amplifier type B
4
19)
Name Plate Language / Type
German / Adhesive foil
G
English / Adhesive foil
E
French / Adhesive foil
F
German / Stainless steel
J
English / Stainless steel
K
French / Stainless steel
L
Design Level
(Specified by ABB)
x
Lay Length
Short, acc. ISO 13359
A
Electrode Design
Standard
1
Conical head, AISI 904L SST (1.4539)
2
20)
Swedish design, Hastelloy C
-4 (2.4610)
3
21)
14) Material certificate for meter tube and flanges
15) > DN8 (5/16 in)
16) Sealing compound (optional): D141B038U01
17) From DN 10 (3/8 in) >= 20 μS/cm
18) Standard up to DN 8 (5/16 in) >= 20 μS/cm, option > DN 8 (5/16 in) >= 5 μS/cm and cable length max. 200 m (660 ft)
19) Option: Up to DN 8 (5/16 in) >= 5 µS/cm, > DN 8 (5/16 in) >= 0.5 µS/cm and cable length max. 200 m (660 ft)
20) For application e.g. with high fat contents
21) DN 50 ... DN 400 (2 ... 16 in), for pulp applications with high resin contents