FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L
Electromagnetic Flowmeter FSM4000
SE41F
XXX X X X X X X X X X X X X X XXX XXX
andard
A
Material certificate 3.1 acc. EN 10204 with pressure test acc. AD2000
D
14)
Pressure test acc. AD2000
Inspection certificate 3.1 acc. EN 10204
F
A
print saved at factory
F
15)
Schutzart / Kabelzuführung
-type conduit fitting M20 x 1.5
2
/ Thread for screw-type conduit fitting NPT 1/2 in
4
/ Thread for screw-type conduit fitting M20 x 1.5
7
16)
IP 68 / Cable connected and connection box potted
8
/ Cable connected and connection box potted NPT 1/2 in
A
17)
-amplifier type A
2
18)
-amplifier type B
4
19)
Name Plate Language / Type
G
E
F
J
English / Stainless steel
K
L
x
A
1
Conical head, AISI 904L SST (1.4539)
2
20)
Swedish design, Hastelloy C
-4 (2.4610)
3
21)
14) Material certificate for meter tube and flanges
15) > DN8 (5/16 in)
16) Sealing compound (optional): D141B038U01
17) From DN 10 (3/8 in) >= 20 μS/cm
18) Standard up to DN 8 (5/16 in) >= 20 μS/cm, option > DN 8 (5/16 in) >= 5 μS/cm and cable length max. 200 m (660 ft)
19) Option: Up to DN 8 (5/16 in) >= 5 µS/cm, > DN 8 (5/16 in) >= 0.5 µS/cm and cable length max. 200 m (660 ft)
20) For application e.g. with high fat contents
21) DN 50 ... DN 400 (2 ... 16 in), for pulp applications with high resin contents
Continued on next page