FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L
Flange DN 700 to 1000 (28 to 40”), steel sensor housing
All specified dimensions and weights are in mm (in) or kg (lb). The specified weights are approximate figures. The maximum
weight is always provided.
Transport lugs
Female thread (either ½″ NPT or M20 x 1.5), see model coding. In the case of a ½” NPT, there is a plug instead of a PG cable
Figure 18: Flange DN 700 to 1000; sensor housing
Dimensions – flange device, aluminum sensor housing (shell housing)
L
F
F1
F2
700 (28”)
1
-1, PN 16
1
-1, PN 10
1
1
150
900 (36”)
1
-1, PN 16
1
1000 (40”)
-1, PN 10
1
1
150
60.6
1 Other pressure ratings on request.
2 If a grounding plate is fitted (fastened to one side of the flange), dimension L increases by 5 mm (0.197 in).
3 If protection plates are fitted (fastened to both sides of the flange), dimension L increases by 10 mm (0.394 in).
4 In devices with high temperature design, the dimensions F, F1 and F2 increase by +127 mm (+5.0 in).
Tolerance for L: DN 700 to 1000 +0 / −10 mm (+0 / −0.394 in)