FSM4000 ELECTROMAGNETIC FLOWMETER | DS/FSM4000-EN REV. L
Model SE41F
Flange DN 450 to 600 (18 to 24), steel sensor housing
All specified dimensions and weights are in mm (in) or kg (lb). The specified weights are approximate figures. The maximum
weight is always provided.
1
Transport lugs
2
Female thread (either ½” NPT or M20 x 1.5), see model coding. In the case of a ½” NPT, there is a plug instead of a PG cable
entry.
Figure 17: Flange DN 450 to 2000; sensor housing
Dimensions - flange device, aluminum sensor housing (shell housing)
Nominal
diameter
Process connection
D
B
L
2 3
C
F
4
F1
4
F2
4
Weight
DN
450 (18")
ASME B16.5, CL 150
635 (25.0)
44.6 (1.76)
686 (27.01)
310 (12.20)
501 (19.72)
515 (20.28)
437 (17.20)
258.5 (570)
AS2129 table D, E
640 (25.20)
DN
500 (20")
EN 1092
-1, PN 10
1
670 (26.38)
33 (1.30)
650 (25.59)
310 (12.20)
501 (19.72)
515 (20.28)
437 (17.20)
188.5 (416)
EN 1092-1, PN 16
1
715 (28.15)
39 (1.54)
238.5 (526)
ASME B16.5, CL
150
698.5 (27.50)
47.9 (1.89)
762 (30.0)
298.5 (658)
AS2129 table D, E
705 (27.76)
650 (25.59)
DN
600 (24")
EN 1092-1, PN 10
1
780 (30.71)
33 (1.30)
780 (30.71)
361 (14.21)
552 (21.73)
566 (22.28)
490 (19.29)
338.5 (746)
EN 1092-1, PN 16
1
840 (33.07)
41 (1.61)
316.5 (698)
ASME B16.5, CL
150
812.8 (32.0)
52.8 (2.08)
914 (35.98)
423.5 (934)
AS2129 table D, E
825 (32.48)
780 (30.71)
1 Other pressure ratings on request.
2 If a grounding plate is fitted (fastened to one side of the flange), dimension L increases by 5 mm (0.197 in).
3 If protection plates are fitted (fastened to both sides of the flange), dimension L increases by 10 mm (0.394 in).
4 In devices with high temperature design, the dimensions F, F1 and F2 increase by +127 mm (+5.0 in).
Tolerance for L: DN 450, DN 500 +0 / −5 mm (+0 / −0.197 in); DN 600 +0 / −10 mm (+0 / −0.394 in)