Installation and commissioning guide
2750 515-1 EN, REV. 14, 2020-06-26
13
G001888
A. Maximum cantilever load at installation angle
B. Maximum cantilever load at installation angle 30°
C. Maximum cantilever load at installation angle 60°
D. Maximum axial static load
E. Load applied at the midpoint
Type Test load 1
minute (N)
Maximum cantilever load in operation at
installation angle (N)
Maximum
axial static
load (N)
30° 60°
GOE 250, 380, 650 5700 2800 2300 1700 20000
GOE 950 5000 2500 2000 1500 20000
GOE 1050 13000 6500 4300 3100 20000
GOE 1175 12000 6000 4300 3100 20000
GOE 1300, 1425 9000 4500 2500 - 20000
GOE 1550, 1675,
1800
13000 6500 4300 1500 20000
GOE 2550 - 1600 13000 6500 3700 1600 20000
GOE 2550 - 1675 12200 6100 2900 - 20000
Maximum permitted torque on the outer terminal
The maximum torque that is permitted on the outer terminal is 250 Nm.