MAINS VOLTAGE
The robot can be connected to a rated voltage of between 200 V and 600 V,
3-phase and protective earthing. A voltage fluctuation of +10% to -15% is permissible
in each connection.
151- Voltage Voltage Voltage
174 200 V
220 V
400 V 400 V
440 V 440 V
475 V 475 V
500 V 500 V
525 V
600 V
CONNECTION OF MAINS
The power is connected either inside the cabinet or to a connector on the cabinet’s left-
hand side. The cable is not supplied. If option 132-133 is chosen, the female connector
(cable part) is included.
131 Cable gland for inside connection. Diameter of cable:
11-12 mm.
133* 32 A, 380-415 V, 3p + PE (see Figure 39).
136* 32 A, 380-415 V, 3p + N + PE (see Figure 39).
Figure 39 CEE male connector.
134 Connection via an industrial Harting 6HSB connector in
accordance with DIN 41640.
35 A, 600 V, 6p + PE (see Figure 40).
Figure 40 DIN male connector.
MAINS SWITCH
141* Rotary switch in accordance with the standard in section 3.2 and IEC 337-1,
VDE 0113.
142 Rotary switch with door interlock.
143 Flange disconnect in accordance with the standard in section 3.2.
Includes door interlock.