- 41 -
000406BG
5 - Installation
During installation do not place the
inverter with the front cover facing
towards the ground.
• Position the bracket
01
so that it is
perfectly level on the wall and use it
as a drilling template. On the bracket
01
there are 9 xing holes; 3 xing
points are enough to support the in-
verter if it is installed on stable, sturdy
supports (Step A).
• Make the necessary holes, using a
drill with a 10 mm bit. The depth of
the holes must be around 70 mm.
(Step A).
• Secure the bracket to the wall with
the 10 mm wall plugs supplied with it
(Step A).
• Hook the 3 screws on the back of
the inverter in correspondence with
the insertion points in the bracket
(Step B).
• Mount the safety bar
02
(highlighted
in blue) on the upper part of the wall-
mounting bracket
01
(Step C).
• Drill 1 hole in correspondence with
the central hole on the lower bracket
04
of the inverter, using a drill with a
10 mm bit. The holes must be appro-
ximately 70 mm deep (Step D)
Anchor the lower part of the inverter
using plugs with a diameter of 10
mm, supplied (Step D).
• Unscrew the 4 screws and open the
front cover
05
in order to make all the
necessary connections.
Do not open the inverter in the
case of rain, snow or a high level
of humidity (>95%)
• Once the connections have been
made, close the cover
05
by tighte-
ning the 4 screws on the front to a mi-
nimum tightening torque of 1.5 Nm.
Wall/Pole mounting