- 41 -
000406BG
5 - Installation
During installation do not place the
inverter with the front cover facing
towards the ground.
Position the bracket
01
so that it is
perfectly level on the wall and use it
as a drilling template. On the bracket
01
there are 9 xing holes; 3 xing
points are enough to support the in-
verter if it is installed on stable, sturdy
supports (Step A).
Make the necessary holes, using a
drill with a 10 mm bit. The depth of
the holes must be around 70 mm.
(Step A).
Secure the bracket to the wall with
the 10 mm wall plugs supplied with it
(Step A).
Hook the 3 screws on the back of
the inverter in correspondence with
the insertion points in the bracket
(Step B).
Mount the safety bar
02
(highlighted
in blue) on the upper part of the wall-
mounting bracket
01
(Step C).
Drill 1 hole in correspondence with
the central hole on the lower bracket
04
of the inverter, using a drill with a
10 mm bit. The holes must be appro-
ximately 70 mm deep (Step D)
Anchor the lower part of the inverter
using plugs with a diameter of 10
mm, supplied (Step D).
Unscrew the 4 screws and open the
front cover
05
in order to make all the
necessary connections.
Do not open the inverter in the
case of rain, snow or a high level
of humidity (>95%)
Once the connections have been
made, close the cover
05
by tighte-
ning the 4 screws on the front to a mi-
nimum tightening torque of 1.5 Nm.