Table 184. Impedance functions, alternatives
Function Function
identification
Ordering no Positi
on
Available
qty
Selected
qty
Notes and
rules
Note: One, and only one alternative can be selected. Selected qty is 0 for other functions in an unselected alternative.
Alternative 1 Distance protection, quadrilateral
Distance protection zone, quadrilateral characteristic ZMQPDIS,
ZMQAPDIS
1MRK005907-AA 1 0-5
Directional impedance quadrilateral ZDRDIR 1MRK005907-BA 2 0-2
Phase selection, quadrilateral characteristic with fixed angle FDPSPDIS 1MRK005907-CA 3 0-2
Alternative 2 Distance protection for series compensated lines, quadrilateral
Phase selection, quadrilateral characteristic with fixed angle FDPSPDIS 1MRK005907-CA 3 0-2
Distance measuring zone, quadrilateral characteristic for series
compensated lines
ZMCPDIS,
ZMCAPDIS
1MRK005907-DA 4 0-5
Directional impedance quadrilateral, including series compensation ZDSRDIR 1MRK005907-EA 5 0-2
Alternative 3 Distance protection, mho (mho for phase - phase fault and mho in parallel with quad for earth fault)
Fullscheme distance protection, mho characteristic ZMHPDIS 1MRK005907-FA 6 0-5
Fullscheme distance protection, quadrilateral for earth faults ZMMPDIS,
ZMMAPDIS
1MRK005907-GA 7 0-5
Directional impedance element for mho characteristic ZDMRDIR 1MRK005907-HA 8 0-2
Additional distance protection directional function for earth faults ZDARDIR 1MRK005907-KA 9 0-2
Mho Impedance supervision logic ZSMGAPC 1MRK005907-LA 10 0-1
Faulty phase identification with load encroachment FMPSPDIS 1MRK005907-MA 11 0-2
Alternative 4 Distance protection, quadrilateral with separate settings for PP and PE
Directional impedance quadrilateral ZDRDIR 1MRK005907-BA 2 0-2
Distance protection zone, quadrilateral characteristic, separate settings ZMRPDIS,
ZMRAPDIS
1MRK005907-NA 12 0-5
Phase selection, quadrilateral characteristic with settable angle FRPSPDIS 1MRK005907-PA 13 0-2
Alternative 5 High speed distance protection, quadrilateral and mho
High speed distance protection, quad and mho characteristic ZMFPDIS 1MRK005907-SB 14 0-1
Alternative 6 High speed distance protection for series compensated lines, quadrilateral and mho
High speed distance protection for series compensated lines, quad and
mho characteristic
ZMFCPDIS 1MRK005907-RB 15 0-1
Optional for alternative 1
Directional impedance element for mho characteristic ZDMRDIR 1MRK005907-HA 8 0-2
Optional for alternative 3
Phase selection, quadrilateral characteristic with fixed angle FDPSPDIS 1MRK005907-CA 3 0-2
Optional for alternatives 1, 2 and 4
Additional distance protection directional function for earth faults ZDARDIR 1MRK005907-KA 9 0-2
Faulty phase identification with load encroachment FMPSPDIS 1MRK005907-MA 11 0-2
Optional with any alternative
Power swing detection ZMRPSB 1MRK005907-UA 16 0-1
Automatic switch onto fault logic, voltage and current based ZCVPSOF 1MRK005908-AA 17 0-1
Power swing logic PSLPSCH 1MRK005907-VA 18 0-1
PoleSlip/Out-of-step protection PSPPPAM 1MRK005908-CB 19 0-1
Out-of-step protection OOSPPAM 1MRK005908-GA 20 0-1
Phase preference logic PPLPHIZ 1MRK005908-DA 22 0-1
Table 185. Current protection
Pos
itio
n
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
C 00 0 00 1 0 0 0 0 0
1MRK 505 346-BEN -
Line differential protection RED670 2.1 IEC
Product version: 2.1