PROFIdrive parameters
103
943 R/W Unsigned16 Selection switch for Status word, bit 15.
(See parameter 939 for coding)
945 R Array[64] Unsigned16 Fault code (coded according to
DRIVECOM profile).
Subindex Contents
1 Active fault
9 **Last ackn. fault
17 **Second last ackn. fault
25 **Third last ackn. fault
33 **Fourth last ackn. fault
41 **Fifth last ackn. fault
947 R Array [64] Unsigned16 Fault number.
Subindex Contents
See parameter 945.
948 R Array [64] Unsigned16 Time difference. Seconds since the last
fault occured.
Subindex Contents
See parameter 945.
952 R/W Unsigned16 Number of faults occured. Writing a zero
clears the value.
953 R Unsigned16 **Last alarm
954 R Unsigned16 **Second last alarm
955 R Unsigned16 **Third last alarm
956 R Unsigned16 **Fourth last alarm
957 R Unsigned16 **Fifth last alarm
958 R Unsigned16 Sixth last alarm (not supported)
959 R Unsigned16 Seventh last alarm (not supported)
960 R Unsigned16 Eighth last alarm (not supported)
961 R Octet String4 Hardware configuration (manufacturer
specific ID of the drive)
Para-
meter
R/W
*