SACE Tmax XT
Tmax low voltage moulded-case circuit-breakers XT5
Operation and maintenance manual for Ekip Touch Trip
Units

Table of Contents

Other manuals for ABB SACE Tmax XT5

Question and Answer IconNeed help?

Do you have a question about the ABB SACE Tmax XT5 and is the answer not in the manual?

Summary

SACE Tmax XT

Operation and maintenance manual for Ekip Touch Trip Units

Manual detailing operation and maintenance for Ekip Touch Trip Units.

Introduction

2 - Safety

Safety requirements and warnings for installation, operation, and maintenance.

Management operations

1 - Putting into service

General pre-ignition inspections and checks before putting into service.

2 - Maintenance and troubleshooting

Routine inspections, cleaning, and fault management procedures.

Protections

1 - Standard Protections

Lists and describes the standard protections available for Ekip Touch models.

2 - Voltage protections

Describes available voltage protections like UV, OV, UV2, OV2, Phase sequence, VU.

3 - Voltage Advanced protections

Details advanced voltage protections: S(V), S2(V), RV.

4 - Frequency protections

Covers frequency protections: UF, OF, UF2, OF2.

5 - Power protections

Details power protections: RP, D, OQ, OP, UP, RQ, Cos φ.

6 - ROCOF protections

ROCOF Protection

Describes the ROCOF protection against rapid frequency variations.

8 - Motor protections

R JAM

Protection against motor block after startup.

R STALL

Protection against motor block during startup.

Protection UC

Protects the motor in reduced or no load conditions.

Protection U

Protects the motor in the event of phase loss.

9 - Additional protections and functions

Synchrocheck

Controls closing actuator based on synchronism conditions between sources.

Measurements

1 - Standard Measurements

Details standard measurements: instantaneous currents, events, trip, min-max, maintenance.

2 - Ekip Measuring Measurements

Covers measurements provided by the Ekip Measuring module.

3 - Class 1 Power & Energy Metering

Performance and characteristics of the Class 1 Power & Energy Metering package.

4 - Datalogger

Describes the Datalogger function for recording data associated with trigger events.

5 - Network Analyzer

Analyzes voltage and current controls over time, including harmonics and sags.

Settings

1 - Main settings

Covers main configuration parameters for Ekip Touch.

Test

1 - Test

Describes test functions like Autotest, Trip Test, and Test CB.

Additional functions

1 - Power Controller

Manages installation loads based on power consumption for efficiency.

2 - Load Shedding

Manages faults in installations with renewable energy sources.

Summary

SACE Tmax XT

Operation and maintenance manual for Ekip Touch Trip Units

Manual detailing operation and maintenance for Ekip Touch Trip Units.

Introduction

2 - Safety

Safety requirements and warnings for installation, operation, and maintenance.

Management operations

1 - Putting into service

General pre-ignition inspections and checks before putting into service.

2 - Maintenance and troubleshooting

Routine inspections, cleaning, and fault management procedures.

Protections

1 - Standard Protections

Lists and describes the standard protections available for Ekip Touch models.

2 - Voltage protections

Describes available voltage protections like UV, OV, UV2, OV2, Phase sequence, VU.

3 - Voltage Advanced protections

Details advanced voltage protections: S(V), S2(V), RV.

4 - Frequency protections

Covers frequency protections: UF, OF, UF2, OF2.

5 - Power protections

Details power protections: RP, D, OQ, OP, UP, RQ, Cos φ.

6 - ROCOF protections

ROCOF Protection

Describes the ROCOF protection against rapid frequency variations.

8 - Motor protections

R JAM

Protection against motor block after startup.

R STALL

Protection against motor block during startup.

Protection UC

Protects the motor in reduced or no load conditions.

Protection U

Protects the motor in the event of phase loss.

9 - Additional protections and functions

Synchrocheck

Controls closing actuator based on synchronism conditions between sources.

Measurements

1 - Standard Measurements

Details standard measurements: instantaneous currents, events, trip, min-max, maintenance.

2 - Ekip Measuring Measurements

Covers measurements provided by the Ekip Measuring module.

3 - Class 1 Power & Energy Metering

Performance and characteristics of the Class 1 Power & Energy Metering package.

4 - Datalogger

Describes the Datalogger function for recording data associated with trigger events.

5 - Network Analyzer

Analyzes voltage and current controls over time, including harmonics and sags.

Settings

1 - Main settings

Covers main configuration parameters for Ekip Touch.

Test

1 - Test

Describes test functions like Autotest, Trip Test, and Test CB.

Additional functions

1 - Power Controller

Manages installation loads based on power consumption for efficiency.

2 - Load Shedding

Manages faults in installations with renewable energy sources.

ABB SACE Tmax XT5 Specifications

General IconGeneral
StandardsIEC 60947-2
Frame SizeXT5
Rated Operational Voltage (Ue)690 V
Number of Poles3, 4
Protection TypeThermal-magnetic