Shutting down the turbocharger
Page 114
April 2015 HZTL2410_EN Revision D
Close the opening in the turbine casing using the cover plate (A).
Fasten the cover plate on the turbine casing (51000) using the
fastening strips (51002), Verbus Ripp® Verbusripp washers (51003)
and nuts (51007) and screw it down securely on the support.
Thoroughly clean the fastening strips (51002) before fitting them. Apply
high-temperature grease to the stud threads (51006).