EasyManuals Logo

ABB TPS57-F Series User Manual

ABB TPS57-F Series
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #122 background imageLoading...
Page #122 background image
Operation Manual / TPS44-F.. - TPS61-F..
Mothballing the turbocharger
10
Taking the engine out of operation for
up to 12 months
10.1
Page 120
© Copyright 2016 ABB. All r
ights reserved.
September 2016 HZTL2412_EN Revision F
If the total acid number (TAN) is greater than 2 mg KOH/g, the following
mothballing measures are necessary after taking an engine out of operation:
Dismantle the turbocharger.
The rotor and the bearing parts must be removed by an official ABB
Turbocharging service station and refitted afterwards.
Clean all parts.
Machined, bright surfaces of steel and cast parts must be oiled with
anticorrosive oil.
Reassemble complete turbocharger.
Rotor turning in stack draught
If the rotor turns as a result of the stack draught:
Install blind flange between compressor casing outlet flange and
charge air duct.

Table of Contents

Other manuals for ABB TPS57-F Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB TPS57-F Series and is the answer not in the manual?

ABB TPS57-F Series Specifications

General IconGeneral
BrandABB
ModelTPS57-F Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals