Entries in engine logbook
By monitoring the engine, conclusions can be drawn about the turbo-
charger performance.
The following operating data and measured values must be entered regu-
larly in the engine manufacturer's engine logbook:
Engine performance and speed
Air intake temperature
Exhaust gas temperature in front of and behind the turbine
Pressure of charge air
Pressure drop in charge air cooler
Lubricating oil pressure and lubricating oil temperature
Air temperature behind compressor and charge air cooler
Turbocharger speed
Pressure loss in air filter
4.2.4
If provided