EasyManua.ls Logo

ABB WaterMaster FET100 - Transmitter; Sensor Cable Connections; Sensor Cable Terminal Connections and Recommended Cable Lengths

ABB WaterMaster FET100
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
WaterMaster FET100
Electromagnetic floweter | Transmitter 3 Electrical Installation
12 OI/FET100–EN Rev. A
3.4 Transmitter / Sensor Cable Connections
3.4.1 Sensor Cable Terminal Connections and Recommended Cable Lengths
Caution.
Make connections only as shown.
Twist the screen wire of D1 / TFE + D2 with the outer screen drain wire and sleeve them.
For standard (non-cathodically protected) systems, connect the drain wire to the earth screw.
For cathodically protected systems, connect the drain wire to terminal SCR, ensuring no braid or
wires touch the exposed copper areas within the transmitter sensor cable wiring area.
If an earth screw is not available at the transmitter enclosure, connect the drain wire to terminal
SCR.
Ensure the seal and mating surfaces are clean to maintain environmental rating.
Conduit connections must provide cable entry sealing.
Ensure cable glands are tightened after wiring. Do not overtighten the plastic cable glands to
avoid destroying their sealing properties. Initially, tighten finger-tight, then a further
1
/2 to
3
/4 turn
using a suitable spanner or wrench.
Fit blanking plugs where required.
Fig. 3.5 Sensor Cable Connections at Transmitter Terminal Block – Standard System
Refer to Section 3.3, page 11 for
cable preparation requirements
before connecting cable
**Drain Wire
(Twisted with
Screen from
D1/TFE – Orange
and D2 – Yellow)
*Inner wire
**For cathodically protected systems (or if the transmitter enclosure does not have an earth screw) connect
the drain wire to terminal SCR.
M1
Brown
M2
Red
SCR
Screen
D1/TFE
Orange
D2
Yell o w
3
Green
(Sleeve)
S2
Blue
(Screen)
S1
Violet
(Screen)
E2
Blue
(*Signal)
E1
Violet
(*Signal)
Cut cables to 70 mm (2.75 in)
Cut cables to 60 mm (2.35 in)