ABB M EAS UREM EN T & ANALYTICS | 21 0 602 6 M NAA
XSeries
G5
User Manual
XFC
G5
/XRC
G5
Accurate, reliable,
capable of measuring
and monitoring gas flow
to AGA, it is API, and
ISO standard.
Measurement made
easy.

Table of Contents

Questions and Answers

  • O
    osborneashleyAug 2, 2025
    What to do if I have remote communication issues with my ABB Measuring Instruments?
    • A
      Angelica AndersonAug 2, 2025
      If you're experiencing remote communication issues with your ABB Measuring Instruments, consider the following steps: * Ensure the symbol flashes in the A8 display position. * Set the port Listen Cycle to zero. * Select Totalflow Remote Protocol in the port configuration. * Increase the cutoff voltage value specified in Station Setup > Remote Comm Cutoff Voltage. * Check the communication port wiring on both the flow computer and the radio. * Confirm that all communication cables are intact and undamaged. * Verify the antenna is properly installed. * Check that the base radio (host device, typically running WinCCU) is working at other locations. * Verify the configuration of the host communication application (typically WinCCU).
  • R
    rbrownAug 16, 2025
    How to fix screen lock up during startup on ABB XRC G5?
    • C
      Christine NguyenAug 16, 2025
      If the screen locks up during startup, try the following: 1. Attach the lithium battery to the board. 2. Perform a warm boot by locating RESET (XFC[G5] S2 and XRC[G5] S6) on the electronic board, then press and hold for 10 seconds. 3. If the warm boot doesn't work, perform a cold boot. Locate the COLDBOOT button (S9) and the RESET button (XFC[G5] S2 and XRC[G5] S6) on the electronic board. Press and hold the COLDBOOT button and at the same time press and hold the RESET button for 10 seconds.

Summary

8 Basic Configuration and Startup

8.1 Setup PCCU for Connection

Steps to set up PCCU for connection.

8.2 Establish Initial Connection

How to establish initial connection with the device.

8.7 Configure Communication

Configuration of communication interfaces.

9 Configure Security (Recommended)

9.6 Configure Role-Based Access Control (RBAC)

Setting up RBAC for user access control.

10 Service and Maintenance

10.1 Preserve Data and Configuration

Importance of backing up data and configuration.

10.4 Restart the System

Overview of system restart options.

11 Calibration

11.1 Measurement Pressure Checks and Calibration

Procedures for pressure checks and calibration.

11.3 RTD Calibration

Calibration procedure for RTD.

11.5 Analog Input Calibration

Calibration for analog inputs.

12 Troubleshooting