RESOLVING ERRORS
18
3. Press the button: The RCCB should now trip and flick the pivot lever of the RCCB
into a centre position (connection to the power supply is interrupted).
4. Switch the circuit breaker completely off (0 position) and then back on by flicking
the pivot lever up into the I position.
5. Lock the cover shield of the wallbox again.
DANGER!
Should the RCCB malfunction during testing, you must not continue to
operate the wallbox under any circumstances!
Please contact your local distributor from whom you have purchased the
wallbox.
Taking the device out of operation
If required, you can take your wallbox temporarily or permanently out of operation. To
deactivate your EVSE 803/813 temporarily, please proceed as follows:
1. Open the cover shield using the key supplied.
2. Flick the pivot lever of the internal RCCB (if present) into the 0 position (connection
to the power supply is interrupted).
3. Lock the cover shield again.
Now the EVSE 803/813 cannot be used for charging.
To deactivate your wallbox permanently, please proceed as follows:
1. Open the cover shield using the key supplied.
2. Flick the pivot lever of the internal RCCB (if present) into the 0 position (connection
to the power supply is interrupted).
3. Lock the cover shield again.
4. In addition, switch off the allocated miniature circuit breaker (MCB) in your up-
stream domestic power distribution box (position 0).
Now the EVSE 803/813 is completely free of electricity and may be demounted if re-
quired.
PLEASE NOTE!
For model variants without RCCB, you must switch off the upstream MCB
in your domestic power distribution box to temporarily or permanently de-
activate the wallbox.
CAUTION!
The electrical de-installation of the EVSE 803/813 must always be car-
ried out by a qualified electrical contractor.

Other manuals for ABL eMH1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABL eMH1 and is the answer not in the manual?

ABL eMH1 Specifications

General IconGeneral
ModeleMH1
CategoryBattery Charger
Charging Power3.7 kW
Connector TypeType 2
Protection ClassIP54
Operating Temperature-25°C to +40°C
Charging Current16 A
Input Voltage230 V

Related product manuals