Installation and Operation Manual
SCL/SCM Series
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Questions and Answers

AC Tech SM004S Specifications

General IconGeneral
BrandAC Tech
ModelSM004S
CategoryDC Drives
LanguageEnglish

Summary

Safety Information

Signal Word and Icon Definitions

Explains safety signal words and icons for hazard identification and procedures.

General Information

Warranty Details

Details the 24-month warranty period and conditions for SCL/SCM AC motor controls.

Safety Precautions

Highlights risks from unauthorized access, misuse, and need for qualified personnel.

Installation Guidelines

Handling and ESD Precautions

Proper handling and precautions for sensitive electronic components are crucial.

Electrical Connection and EMC

Adherence to national/local codes and EMC requirements for installation.

Application Safety

Drive not for safety functions; external devices needed for safety like E-stops.

Specifications

Installation Procedures

Environmental and Mounting Requirements

Details installation environment, spacing, orientation, and enclosure needs.

Installation After Storage

Warns of capacitor damage after long storage and provides capacitor reforming procedure.

Input AC Power Requirements

Power Wiring Procedures

Power Wiring Diagrams

Control Wiring Best Practices

Control Wiring Diagrams

Initial Power Up and Motor Rotation Check

Motor Rotation Verification

Explains how to check and correct motor rotation direction after initial power-up.

Programming the Drive

Programming via Drive Buttons and Display

Guides on entering PROGRAM mode, password, and accessing parameters.

Navigating and Editing Parameters

Details scrolling through parameters and changing values using buttons.

Parameter Menu Overview

Parameter Details (P01-P12)

Details parameters related to line voltage, carrier frequency, start/stop methods, and I/O functions.

Parameter Details (P12-P29)

Details parameters for TB-13E functions, control, units editing, rotation, and acceleration.

Parameter Descriptions

Acceleration Time (P19)

Sets acceleration rate from 0 Hz to Base Frequency for all speed sources.

Deceleration Time (P20)

Sets deceleration rate from Base Frequency to 0 Hz.

Motor Overload Protection (P26)

Details built-in overload protection, setting motor current ratio.

Base Frequency (P27)

Sets output frequency for full voltage, defining V/Hz ratio for motor torque.

Program Selection (P48)

Selects operating mode (User/OEM) and parameter reset options.

Troubleshooting Guide

Fault Messages and Causes

Lists fault codes, descriptions, and possible causes for drive shutdowns.

Fault Clearing and Restart Behavior

Explains how to clear faults and the drive's automatic restart attempts after a fault.

Drive Display Messages

Status and Warning Message Codes

Lists and describes status/warning messages like Fault Lockout, Current Limit, etc.