Questions and Answers

  • A
    aboyerAug 12, 2025
    Why am I getting a High DC Bus Voltage Fault on my AC Tech SM420 DC Drives?
    • T
      Timothy NixonAug 12, 2025
      A high DC bus voltage fault in AC Tech DC Drives can occur due to several reasons: the line voltage might be too high, the deceleration rate might be too fast, or there could be an overhauling load. For fast deceleration or overhauling loads, dynamic braking may be required.
  • M
    michaelapadillaAug 16, 2025
    What to do if AC Tech DC Drives show Incompatibility Fault?
    • T
      Tiffany MorrisAug 16, 2025
      If you're encountering an Incompatibility Fault with your AC Tech DC Drives, it means an EPM with an incompatible parameter version has been installed. You can either remove the EPM or perform a factory reset using Parameter 48 to change the parameter version of the EPM to match that of the drive.
  • C
    Catherine DiazAug 19, 2025
    How to resolve Control Fault on AC Tech SM420?
    • C
      Carla BennettAug 19, 2025
      A Control Fault in AC Tech DC Drives means that a blank EPM or an EPM with corrupted data has been installed. To resolve this, perform a factory reset using Parameter 48 - PROGRAM SELECTION.
  • T
    timothyfloresAug 23, 2025
    What does External Fault mean on AC Tech DC Drives?
    • R
      Raven PaulAug 23, 2025
      An External Fault in AC Tech DC Drives is triggered when one of the TB-13 terminals is set as an External Fault input and that terminal is open with respect to TB-11. Refer to Parameters 10, 11, and 12.
  • W
    wardanthonyAug 27, 2025
    Why AC Tech SM420 show Start Fault?
    • S
      Steven McculloughAug 27, 2025
      A Start Fault in AC Tech DC Drives occurs when a start command was present when the drive was powered up. If START METHOD is set to NORMAL, you must wait 2 seconds after power-up to apply the Start command.
  • F
    Frederick DurhamAug 31, 2025
    What causes Low DC Bus Voltage Fault in AC Tech SM420 DC Drives?
    • C
      crystalballAug 31, 2025
      A Low DC Bus Voltage Fault in AC Tech DC Drives indicates that the line voltage is too low.
  • M
    Michele AliSep 3, 2025
    What does Dynamic Braking Fault mean in AC Tech DC Drives?
    • T
      Terry WelchSep 3, 2025
      A Dynamic Braking Fault in AC Tech DC Drives means that the drive has detected that the dynamic braking resistors are overheating.
  • D
    Donald QuinnSep 7, 2025
    What does Data Fault mean in AC Tech SM420 DC Drives?
    • H
      heatherbernardSep 7, 2025
      A Data Fault in AC Tech DC Drives means that user data and OEM defaults in the EPM are corrupted.

Summary

Safety Information

GENERAL

Warranty

Covers the 24-month warranty for SCL/SCM AC motor controls from shipment.

Safety Information

Highlights risks of electrically live parts and inappropriate handling.

INSTALLATION

ELECTRICAL CONNECTION

Guidelines for safe electrical installation and adherence to regulations.

SCL;SCM SPECIFICATIONS

SCL;SCM RATINGS

INPUT AC POWER REQUIREMENTS

Input Fusing Requirements

Input Wire Size Requirements

Installation According to EMC Requirements

POWER WIRING

Input and Output Wiring

Instructions for wiring input power and output to the motor, including conduit separation.

CONTROL WIRING

Speed Reference Selection

Two-Wire Start;Stop Control

Three-Wire Start;Stop Control

Preset Speeds & Speed Pot (2-Wire Start;Stop Control)

INITIAL POWER UP AND MOTOR ROTATION

PROGRAMMING THE SCL;SCM DRIVE

Setting Values in Tenths of Units Above 100

DESCRIPTION OF PARAMETERS

TROUBLESHOOTING

FAULT MESSAGES

SCL;SCM DISPLAY MESSAGES

Status and Warning Messages

AC Tech SM420 Specifications

General IconGeneral
BrandAC Tech
ModelSM420
CategoryDC Drives
LanguageEnglish

Related product manuals