Installation and Operation Manual
SCL/SCM Series
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Questions and Answers

  • K
    Kimberly PetersAug 12, 2025
    Why am I getting a High DC Bus Voltage Fault on my AC Tech SM230?
    • I
      imaldonadoAug 13, 2025
      A high DC bus voltage fault in AC Tech DC Drives can occur due to several reasons: the line voltage might be too high, the deceleration rate might be too fast, or there could be an overhauling load. For fast deceleration or overhauling loads, dynamic braking may be required.
  • E
    Erica GarciaAug 16, 2025
    What to do if AC Tech SM230 show Incompatibility Fault?
    • M
      Michael HillAug 16, 2025
      If you're encountering an Incompatibility Fault with your AC Tech DC Drives, it means an EPM with an incompatible parameter version has been installed. You can either remove the EPM or perform a factory reset using Parameter 48 to change the parameter version of the EPM to match that of the drive.
  • A
    Alan OwensAug 20, 2025
    How to resolve Control Fault on AC Tech SM230?
    • J
      jennifer58Aug 20, 2025
      A Control Fault in AC Tech DC Drives means that a blank EPM or an EPM with corrupted data has been installed. To resolve this, perform a factory reset using Parameter 48 - PROGRAM SELECTION.
  • G
    Gary HollandAug 23, 2025
    What does External Fault mean on AC Tech SM230 DC Drives?
    • S
      Stanley BallAug 25, 2025
      An External Fault in AC Tech DC Drives is triggered when one of the TB-13 terminals is set as an External Fault input and that terminal is open with respect to TB-11. Refer to Parameters 10, 11, and 12.
  • P
    Paul RyanAug 27, 2025
    Why AC Tech SM230 show Start Fault?
    • M
      melendezkimberlyAug 27, 2025
      A Start Fault in AC Tech DC Drives occurs when a start command was present when the drive was powered up. If START METHOD is set to NORMAL, you must wait 2 seconds after power-up to apply the Start command.
  • G
    garciakennethAug 31, 2025
    What causes Low DC Bus Voltage Fault in AC Tech SM230?
    • A
      alvarezcoreyAug 31, 2025
      A Low DC Bus Voltage Fault in AC Tech DC Drives indicates that the line voltage is too low.
  • G
    Gary DaltonSep 3, 2025
    What does Dynamic Braking Fault mean in AC Tech SM230 DC Drives?
    • W
      William FletcherSep 3, 2025
      A Dynamic Braking Fault in AC Tech DC Drives means that the drive has detected that the dynamic braking resistors are overheating.
  • D
    Dominique WebsterSep 7, 2025
    What does Data Fault mean in AC Tech SM230?
    • A
      Andrew VincentSep 7, 2025
      A Data Fault in AC Tech DC Drives means that user data and OEM defaults in the EPM are corrupted.

Summary

1 GENERAL

1.1 Products Covered in This Manual

Covers AC Tech SCL and SCM Series Variable Frequency Drives.

1.3 Warranty

Outlines the 24-month warranty for SCL/SCM AC motor controls.

1.5 Safety Information

Highlights safety information regarding electrically live parts and proper handling.

6 INSTALLATION

6.1 Installation After a Long Period of Storage

Procedures to reform DC bus capacitors after prolonged storage to prevent damage.

7 INPUT AC POWER REQUIREMENTS

7.1 Input Voltage Ratings

Specifies acceptable input voltage ranges for SM000S, SM200S/SL200S, SM200, and SM400 series.

7.2 Input Fusing Requirements

Provides recommended circuit breaker and fuse ratings for various voltage and phase configurations.

8 POWER WIRING

8.1 Input and Output Wiring

Details wiring procedures for input power and output motor connections, including conduit separation.

12 INITIAL POWER UP AND MOTOR ROTATION

AC Tech SM230 Specifications

General IconGeneral
ModelSM230
CategoryDC Drives
Input Voltage115/230 VAC
Output Voltage0-180 VDC
Protection FeaturesOvervoltage, Short Circuit
Operating Temperature0°C to 40°C
Humidity5% to 95% (non-condensing)