Questions and Answers

  • M
    Morgan WestAug 13, 2025
    Why am I getting a High DC Bus Voltage Fault on my AC Tech DC Drives?
    • R
      Richard HarrisAug 13, 2025
      A high DC bus voltage fault in AC Tech DC Drives can occur due to several reasons: the line voltage might be too high, the deceleration rate might be too fast, or there could be an overhauling load. For fast deceleration or overhauling loads, dynamic braking may be required.
  • J
    jasonwoodardAug 17, 2025
    What to do if AC Tech SM230S show Incompatibility Fault?
    • S
      Sabrina CopelandAug 17, 2025
      If you're encountering an Incompatibility Fault with your AC Tech DC Drives, it means an EPM with an incompatible parameter version has been installed. You can either remove the EPM or perform a factory reset using Parameter 48 to change the parameter version of the EPM to match that of the drive.
  • J
    Jodi DavisAug 21, 2025
    How to resolve Control Fault on AC Tech DC Drives?
    • P
      ppatelAug 21, 2025
      A Control Fault in AC Tech DC Drives means that a blank EPM or an EPM with corrupted data has been installed. To resolve this, perform a factory reset using Parameter 48 - PROGRAM SELECTION.
  • C
    Carl MartinAug 25, 2025
    What does External Fault mean on AC Tech DC Drives?
    • C
      Christina ShepardAug 26, 2025
      An External Fault in AC Tech DC Drives is triggered when one of the TB-13 terminals is set as an External Fault input and that terminal is open with respect to TB-11. Refer to Parameters 10, 11, and 12.
  • G
    Gregory PetersAug 28, 2025
    Why AC Tech SM230S DC Drives show Start Fault?
    • D
      David KimAug 28, 2025
      A Start Fault in AC Tech DC Drives occurs when a start command was present when the drive was powered up. If START METHOD is set to NORMAL, you must wait 2 seconds after power-up to apply the Start command.
  • B
    boonejulieSep 1, 2025
    What causes Low DC Bus Voltage Fault in AC Tech DC Drives?
    • L
      Lynn RamseySep 1, 2025
      A Low DC Bus Voltage Fault in AC Tech DC Drives indicates that the line voltage is too low.
  • T
    thompsonjohnSep 5, 2025
    What does Dynamic Braking Fault mean in AC Tech SM230S?
    • J
      James Mitchell IISep 5, 2025
      A Dynamic Braking Fault in AC Tech DC Drives means that the drive has detected that the dynamic braking resistors are overheating.
  • C
    Cynthia FreemanSep 8, 2025
    What does Data Fault mean in AC Tech DC Drives?
    • K
      Kelly RiveraSep 9, 2025
      A Data Fault in AC Tech DC Drives means that user data and OEM defaults in the EPM are corrupted.

Summary

General Information

Safety Information Overview

Highlights risks of electrical shock, hot surfaces, and improper use of the drive.

Safety Information

Installation

Electrical Connection and Application Notes

Covers electrical connection regulations, safety, and application constraints for the drive.

SCL;SCM Ratings

Model Input;Output and Heat Loss Ratings

Provides detailed ratings for SCL/SCM models, including input/output current and heat loss.

Input AC Power Requirements

Input Fusing Requirements

Specifies circuit breaker and fuse ratings required for installation according to NEC/local codes.

Power Wiring

Input and Output Wiring Procedures

Instructions for wiring input power and output to the motor, including conduit separation.

Control Wiring

Speed Reference Signals (Pot, VDC, mA)

Details analog speed reference inputs like Speed Pot, 0-10 VDC, and 4-20 mA.

Speed Reference Selection and Modes

Describes programming terminals for speed references, preset speeds, and jog modes.

Control Wiring Diagrams

Two-Wire Start;Stop Control Wiring

Wiring diagram and notes for implementing a two-wire start/stop control scheme.

Three-Wire Start;Stop Control Wiring

Wiring diagram and notes for implementing a three-wire start/stop control scheme.

Initial Power Up and Motor Rotation

Programming the SCL;SCM Drive

Parameter Menu

Parameter Descriptions

P03 Start Method Options

Defines how the drive starts, including normal, power-up, and auto-restart options.

P04 Stop Method Options

Defines how the drive stops (Coast, Coast with DC Brake, Ramp, Ramp with DC Brake).

P05 Standard Speed Source Selection

Selects the speed reference source when in standard speed mode (Keypad, Preset, VDC, mA).

P25 Current Limit Setting

Sets the maximum allowable output current of the drive.

P26 Motor Overload Protection

Provides solid-state motor overload protection; set to motor current rating percentage.

P31-P37 Preset Speed Configuration

Activates preset speeds via contact closures on TB-11, TB-13A, 13B, 13E.

P48 Program Selection and Reset

Selects operation mode (User/OEM) and resets parameters to defaults.

Troubleshooting

Accessing Fault History and Parameters

Guide to troubleshooting drive issues, accessing fault history and parameters.

Fault Messages and Causes

Lists fault codes, their descriptions, and possible causes for drive shutdown.

AC Tech SM230S Specifications

General IconGeneral
BrandAC Tech
ModelSM230S
CategoryDC Drives
LanguageEnglish