Installation and Operation Manual
SCL/SCM Series
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Questions and Answers

  • M
    Martin McculloughAug 12, 2025
    Why am I getting a High DC Bus Voltage Fault on my AC Tech DC Drives?
    • M
      mwilsonAug 12, 2025
      A high DC bus voltage fault in AC Tech DC Drives can occur due to several reasons: the line voltage might be too high, the deceleration rate might be too fast, or there could be an overhauling load. For fast deceleration or overhauling loads, dynamic braking may be required.
  • P
    perrythomasAug 16, 2025
    What to do if AC Tech DC Drives show Incompatibility Fault?
    • M
      Mark WeberAug 16, 2025
      If you're encountering an Incompatibility Fault with your AC Tech DC Drives, it means an EPM with an incompatible parameter version has been installed. You can either remove the EPM or perform a factory reset using Parameter 48 to change the parameter version of the EPM to match that of the drive.
  • V
    Vanessa Schmidt DDSAug 20, 2025
    How to resolve Control Fault on AC Tech DC Drives?
    • E
      emma53Aug 20, 2025
      A Control Fault in AC Tech DC Drives means that a blank EPM or an EPM with corrupted data has been installed. To resolve this, perform a factory reset using Parameter 48 - PROGRAM SELECTION.
  • S
    Stephen LeeAug 25, 2025
    What does External Fault mean on AC Tech SM220S DC Drives?
    • H
      Hunter FrazierAug 25, 2025
      An External Fault in AC Tech DC Drives is triggered when one of the TB-13 terminals is set as an External Fault input and that terminal is open with respect to TB-11. Refer to Parameters 10, 11, and 12.
  • L
    Lisa SmithAug 27, 2025
    Why AC Tech SM220S DC Drives show Start Fault?
    • L
      Laura LloydAug 27, 2025
      A Start Fault in AC Tech DC Drives occurs when a start command was present when the drive was powered up. If START METHOD is set to NORMAL, you must wait 2 seconds after power-up to apply the Start command.
  • F
    fosterdavidAug 31, 2025
    What causes Low DC Bus Voltage Fault in AC Tech SM220S?
    • J
      Jonathan KochAug 31, 2025
      A Low DC Bus Voltage Fault in AC Tech DC Drives indicates that the line voltage is too low.
  • J
    Jared HaydenSep 4, 2025
    What does Dynamic Braking Fault mean in AC Tech SM220S DC Drives?
    • W
      William CurrySep 4, 2025
      A Dynamic Braking Fault in AC Tech DC Drives means that the drive has detected that the dynamic braking resistors are overheating.
  • K
    Kimberly CummingsSep 7, 2025
    What does Data Fault mean in AC Tech DC Drives?
    • A
      angelakeySep 8, 2025
      A Data Fault in AC Tech DC Drives means that user data and OEM defaults in the EPM are corrupted.

Summary

1 GENERAL

1.3 Warranty

Covers defects in material and workmanship for 24 months from shipment date.

1.5 Safety Information

Warns of electrical hazards and need for qualified personnel.

6 INSTALLATION

ELECTRICAL CONNECTION

Guidelines for electrical installation, safety regulations, and codes.

APPLICATION

Specifies that the drive is not a safety device and must not be used for critical safety functions.

4 SCL;SCM SPECIFICATIONS

5 SCL;SCM RATINGS

7 INPUT AC POWER REQUIREMENTS

DANGER!

Warning about electrical shock due to stored charge in capacitors.

7.1 Input Voltage Ratings

Details input voltage ranges for SM000S, SM200S, SL200S, SM200, and SM400 series.

7.2 Input Fusing Requirements

WARNING! on RCDs

Warns about DC current in protective conductor and RCD type requirements.

7.3 Input Wire Size Requirements

8 POWER WIRING

8.1 Input and Output Wiring

Instructions for wiring input power and output motor connections.

9 SCL;SCM POWER WIRING DIAGRAM

WARNING! Wiring Precautions

Caution against connecting AC to output terminals or B+/B- and leakage current.

10 CONTROL WIRING

10.5 Speed Reference Signals

Explains analog speed reference inputs like speed pots, 0-10 VDC, and 4-20 mA.

10.6 Speed Reference Selection

Details how to select speed references via terminals and parameters.

JOG Mode Warnings

Critical warning about JOG mode and STOP signal behavior.

11.2 Two-Wire Start;Stop Control

Two-Wire Control Notes

Instructions for RUN/STOP, reverse direction, and speed source setup.

11.3 Three-Wire Start;Stop Control

Three-Wire Control Notes

Guides on programming for start/stop, reverse, and speed source.

11.4 Preset Speeds & Speed Pot (2-Wire Start;Stop Control)

Preset Speed and Speed Pot Notes

Instructions for programming preset speeds and speed pot control.

12 INITIAL POWER UP AND MOTOR ROTATION

DANGER! Electrical Shock Hazard

Electrical shock hazard warning due to charged capacitors.

STOP! Wiring and Powering Warnings

Warnings against incorrect output connections and rapid power cycling.

13 PROGRAMMING THE SCL;SCM DRIVE

13.2 Electronic Programming Module (EPM)

Describes the EPM's function, removability, and use for quick setup.

14 PARAMETER MENU

15 DESCRIPTION OF PARAMETERS

P01 LINE VOLTAGE SELECTION

Calibrates drive for applied input voltage (HIGH/LOW).

P02 CARRIER FREQUENCY

Sets switching rate for motor noise reduction.

P03 START METHOD

Defines how the drive starts (e.g., normal, on power up).

Automatic Start Warning

Warns about automatic starting causing injury or damage.

P04 STOP METHOD

Defines stop methods: Coast, Coast with DC Brake, Ramp, Ramp with DC Brake.

P05 STANDARD SPEED SOURCE

Selects speed reference source when in STANDARD speed mode.

P10 TB-13 A FUNCTION SELECT

Selects function for terminal TB-13A.

P11 TB-13 B FUNCTION SELECT

Selects function for terminal TB-13B.

P12 TB-13 E FUNCTION SELECT

Selects input or output functions for terminal TB-13E.

P14 CONTROL

Selects source for START/STOP and direction commands.

P17 ROTATION DIRECTION

Sets rotation direction (forward only or both).

P19 ACCELERATION TIME

Sets acceleration rate from 0 Hz to BASE FREQUENCY.

P48 PROGRAM SELECTION

Selects user/OEM settings and resets parameters to defaults.

16 TROUBLESHOOTING

FAULT MESSAGES

Lists fault codes, their descriptions, and possible causes.

17 SCL;SCM DISPLAY MESSAGES

AC Tech SM220S Specifications

General IconGeneral
ModelSM220S
CategoryDC Drives
Frequency50/60 Hz
Input Voltage115/230V AC
Output Voltage0-180V DC
Operating Temperature0°C to 40°C
Storage Temperature-20°C to 60°C
Protection FeaturesOvercurrent, Overtemperature, Short Circuit