Questions and Answers

  • J
    Jerry WoodAug 13, 2025
    Why am I getting a High DC Bus Voltage Fault on my AC Tech SM210 DC Drives?
    • J
      Joshua HesterAug 13, 2025
      A high DC bus voltage fault in AC Tech DC Drives can occur due to several reasons: the line voltage might be too high, the deceleration rate might be too fast, or there could be an overhauling load. For fast deceleration or overhauling loads, dynamic braking may be required.
  • B
    bennetthollyAug 17, 2025
    What to do if AC Tech SM210 show Incompatibility Fault?
    • J
      Joseph AndersonAug 17, 2025
      If you're encountering an Incompatibility Fault with your AC Tech DC Drives, it means an EPM with an incompatible parameter version has been installed. You can either remove the EPM or perform a factory reset using Parameter 48 to change the parameter version of the EPM to match that of the drive.
  • R
    Ryan BarberAug 21, 2025
    How to resolve Control Fault on AC Tech DC Drives?
    • J
      Jason CookAug 21, 2025
      A Control Fault in AC Tech DC Drives means that a blank EPM or an EPM with corrupted data has been installed. To resolve this, perform a factory reset using Parameter 48 - PROGRAM SELECTION.
  • A
    angela01Aug 25, 2025
    What does External Fault mean on AC Tech SM210?
    • C
      Courtney SimpsonAug 26, 2025
      An External Fault in AC Tech DC Drives is triggered when one of the TB-13 terminals is set as an External Fault input and that terminal is open with respect to TB-11. Refer to Parameters 10, 11, and 12.
  • T
    Tracy ColemanAug 28, 2025
    Why AC Tech SM210 DC Drives show Start Fault?
    • R
      Ryan FloydAug 28, 2025
      A Start Fault in AC Tech DC Drives occurs when a start command was present when the drive was powered up. If START METHOD is set to NORMAL, you must wait 2 seconds after power-up to apply the Start command.
  • L
    lucaspaulSep 1, 2025
    What causes Low DC Bus Voltage Fault in AC Tech SM210?
    • B
      Brandon ShawSep 1, 2025
      A Low DC Bus Voltage Fault in AC Tech DC Drives indicates that the line voltage is too low.
  • J
    Jeffrey MurphySep 4, 2025
    What does Dynamic Braking Fault mean in AC Tech SM210?
    • G
      Gregory DiazSep 4, 2025
      A Dynamic Braking Fault in AC Tech DC Drives means that the drive has detected that the dynamic braking resistors are overheating.
  • K
    kduncanSep 8, 2025
    What does Data Fault mean in AC Tech DC Drives?
    • K
      Kimberly KnightSep 9, 2025
      A Data Fault in AC Tech DC Drives means that user data and OEM defaults in the EPM are corrupted.

Summary

1 GENERAL

1.5 Safety Information

General safety precautions and warnings for drive operation and handling.

6 INSTALLATION

7 INPUT AC POWER REQUIREMENTS

7.2 Input Fusing Requirements

Details required circuit breaker or fuse ratings for installation.

7.4 Installation According to EMC Requirements

Guidelines for meeting Electromagnetic Compatibility (EMC) standards.

8 POWER WIRING

8.1 Input and Output Wiring

Instructions for connecting input power and output motor wires.

10 CONTROL WIRING

12 INITIAL POWER UP AND MOTOR ROTATION

13 PROGRAMMING THE SCL;SCM DRIVE

15 DESCRIPTION OF PARAMETERS

Line Voltage and Carrier Frequency Settings

Parameters P01-P02 for configuring input voltage and carrier frequency.

Start and Stop Methods

Parameters P03-P04 defining drive start/stop behavior.

Speed Reference and Control Inputs

Parameters P05-P12 for selecting speed sources and terminal functions.

Key Parameters for Operation

Important parameters for acceleration, current limit, presets, and programming.

Troubleshooting and Status Parameters

Parameters P47-P58 for fault history, status, and diagnostics.

16 TROUBLESHOOTING

17 SCL;SCM DISPLAY MESSAGES