EasyManua.ls Logo

AC Tech SM210 - Preset Speeds & Speed Pot (2-Wire Start;Stop Control)

AC Tech SM210
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
21 SM01P
11.4 Preset Speeds & Speed Pot (2-Wire Start/Stop Control)
Maintained
RUN/STOP
Contact
1
2
25
13A
13E13B
RUN
5 6
11
16
17
SIGNAL COMMON
0-10V DC INPUT
TB-13A FUNCTION SELECT
TB-13B FUNCTION SELECT
TB-13E FUNCTION SELECT
FORM A RELAY
SPEED POT POWER SUPPLY
DIGITAL INPUT REFERENCE
(PRESET SPEED #1)
(PRESET SPEED #2)
(PRESET SPEED #3)
SPEED
POT
Speed Potentiometer
NOTE:
For preset speed control, all or some of the TB-13 terminals must be
programmed as preset speed selects. If only two or three preset speeds are
required, only two of the TB-13 terminals must be used. Refer to the table in
the description of Parameters 31-37 in Section 15.
Program the PRESET SPEEDS (Parameters 31-37) to the desired values.
If speed pot control is desired when none of the preset speeds are selected (all
preset speed selects are open to TB-11), set STANDARD SPEED SOURCE
(Parameter 05) to 0-10 VDC (03).
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com