Installation and Operation Manual
SCL/SCM Series
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Questions and Answers

  • T
    Thomas SandersAug 13, 2025
    Why am I getting a High DC Bus Voltage Fault on my AC Tech DC Drives?
    • C
      Christopher StanleyAug 13, 2025
      A high DC bus voltage fault in AC Tech DC Drives can occur due to several reasons: the line voltage might be too high, the deceleration rate might be too fast, or there could be an overhauling load. For fast deceleration or overhauling loads, dynamic braking may be required.
  • G
    George HamiltonAug 16, 2025
    What to do if AC Tech SM430 DC Drives show Incompatibility Fault?
    • C
      Cory ChristensenAug 16, 2025
      If you're encountering an Incompatibility Fault with your AC Tech DC Drives, it means an EPM with an incompatible parameter version has been installed. You can either remove the EPM or perform a factory reset using Parameter 48 to change the parameter version of the EPM to match that of the drive.
  • D
    Dr. Christopher KingAug 20, 2025
    How to resolve Control Fault on AC Tech SM430?
    • B
      Bradley BeardAug 20, 2025
      A Control Fault in AC Tech DC Drives means that a blank EPM or an EPM with corrupted data has been installed. To resolve this, perform a factory reset using Parameter 48 - PROGRAM SELECTION.
  • H
    hpriceAug 25, 2025
    What does External Fault mean on AC Tech SM430?
    • H
      hancockmaryAug 25, 2025
      An External Fault in AC Tech DC Drives is triggered when one of the TB-13 terminals is set as an External Fault input and that terminal is open with respect to TB-11. Refer to Parameters 10, 11, and 12.
  • K
    Kenneth BurkeAug 27, 2025
    Why AC Tech DC Drives show Start Fault?
    • L
      Lori CordovaAug 28, 2025
      A Start Fault in AC Tech DC Drives occurs when a start command was present when the drive was powered up. If START METHOD is set to NORMAL, you must wait 2 seconds after power-up to apply the Start command.
  • D
    Daniel MartinezAug 31, 2025
    What causes Low DC Bus Voltage Fault in AC Tech SM430 DC Drives?
    • T
      Tiffany SullivanAug 31, 2025
      A Low DC Bus Voltage Fault in AC Tech DC Drives indicates that the line voltage is too low.
  • J
    jeremygreenSep 4, 2025
    What does Dynamic Braking Fault mean in AC Tech DC Drives?
    • E
      Elizabeth ClaytonSep 5, 2025
      A Dynamic Braking Fault in AC Tech DC Drives means that the drive has detected that the dynamic braking resistors are overheating.
  • H
    Heather CabreraSep 8, 2025
    What does Data Fault mean in AC Tech DC Drives?
    • J
      James Rios IISep 8, 2025
      A Data Fault in AC Tech DC Drives means that user data and OEM defaults in the EPM are corrupted.

Summary

Installation

Installation After Long Storage

Procedures for safely operating the drive after extended periods of inactivity.

Input AC Power Requirements

Input Fusing Requirements

Specifies required circuit breakers and fuses for safe operation.

Control Wiring

Speed Reference Selection Methods

Explains how to select speed control sources like keypad, analog signals, or preset speeds.

Programming the SCL;SCM Drive

Electronic Programming Module (EPM)

Details the function and use of the removable EPM for drive configuration.

Description of Parameters

Troubleshooting

AC Tech SM430 Specifications

General IconGeneral
ModelSM430
CategoryDC Drives
Enclosure RatingNEMA 1 (IP20)
Input Voltage115/230 VAC ±10%, 50/60 Hz
Communication OptionsModbus RTU
Operating Temperature0 to 40°C (32 to 104°F)