3.8 Bill Density Detection Function
This feature will allow you to detect when two bills stuck together each other try
to pass through the unit. Also if a bill doesn’t meet the tness requirements it will
be detected by the unit.
To activate it, press down the “ADD” button for 3 sec, the current level adjustment
will come out on the display (IR-X). The function can be adjusted in the range of
0-9 using the + and – keys.
IR-0 means the function is disabled.
3.9 “BATCH” Function
By pressing the BATCH button sequentially, the preset batching value will change
from 100, 50, 20 and 10.
Custom batching can be set up in case the user needs a different amount. The
user must select the nearest preset batching value and reach the nal value us-
ing the + and – keys.
To clear this function, press the “BATCH” button to clear the indicator on the
display.
Once the hopper is loaded, the machine will start counting and will stop when the
counted quantity reaches the preset batch quantity.
To repeat the batch counting operation under the same preset batch quantity, just
remove the counted bills from the stacker.
23