WinCEGeräte_Handbuch_Administration_v2 00_en 17 / 84
2.2.2.5 Program parameters
Parameters Definition
Status indicator
-s=connection
-s=akku
Displays connection status (valid IP) (adapter: -a)
Shows / closes battery status (if 'close' is enabled)
-s=signal
Shows / closes field strength (if ‘close’ is enabled)
-s=clockanalog
Shows time in analogue format
-s=clockdigi
Shows time in digital format
Window position
-x=
X position of icon
-y=
Y position of icon
Status indicator - small
-small
Battery / signal status is displayed as a bar
Window size
-w=
Width of icon
-h=
Height of icon
Position (view)
-v=topmost
Icon over all other windows (default)
-v=desktop
Icon embedded in desktop
Sliding window
-slide
Sliding icon
Shows coordinates
-coord
Shows the current coordinates after moving the icon
Connection settings
-a=
Adapter to check the connection status.
Separate several adapters with a semicolon (;).
-p=
Host that is pinged to test the availability of the connection (ARP).
Time settings
-nosec
Does not display seconds (with ClockAnalog or ClockDigi)
-12h
12-hour display (with ClockDigi)
Battery options
-akkuwarn
Message dialogue box (once) and flashing of battery icon when
battery status is low.
-akkubeep
Cyclic beep with critical battery status.
Language setting
-l=de
Messages / texts in German
-l=en
Messages / texts in English
-l=it
Messages / texts in Italian
-l=fr
Messages / texts in French
Closes status indicator
-close
The relevant status icon is closed depending on the parameter ‘-s’.
If ‘-s’ is not defined, all status indicators are closed
Tab. 2: ACDStatView command line parameter