P1166 / P1266 / P1266i / P1166P / P1266P
Condential
4-1
Chapter 4
Function Test & Alignment Procedure
4-1 Test Equipment Needed
- IBM PC with XGA resolution and Wireless Network Card
- DVD player with Multi-system (NTSC/PAL/SECAM), equipped “Component”, “S-Video” ,
“Composite” and "HDMI".
- HDTV Source (480P, 720P, 1080P)
- Minolta CL-100
- Quantum Data 802B or CHROMA2327 (Color Video Signal & Pattern Generator)
- After changing parts, check the information below.
4-2 Service Mode
1. Turn on the projector and input the signal
2. Do the following actions sequentially to get into service mode
(1) Press "Power→Left→Left→Menu".
(2) Service mode will be shown.
(3) After conrming the conguration, press "Exit" to exit.
4-3 OSD Reset
1. After nal QC step, we have to erase all saved change again and restore the OSD
default setting. The following actions will allow you to erase all end-users' settings and
restore the default setting:
(1) Please get into OSD menu.
(2) To execute "Reset" function.