EXAMPLE 03 : Master/slave driver system
DESCRIPTION :
Set FA1=13 for 1st (Master) speed signal input terminal.
Set FA2=11 for maximum speed setting
87
0 - 100%
10V FA1 FA2 GND 10V FA1 FA2 GND
0 - 200%
10V FA1 FA2 GND
0 - 50%
A B C
rate A
10k 10k
rate B
10k
rate C
5KB Master
Number A B C
Speed rate 1 2 0.5
Function setting
CD12 = 1
CD14 = 100
CD44 = 13
CD45 = 11
CD12 = 1
CD14 = 200
CD44 = 13
CD45 = 11
CD12 = 1
CD14 = 50
CD44 = 13
CD45 = 11
Fmax
(SPEED)
B
A
C
Master
B 200HZ
A 100HZ
C 50HZ
Analong input
rate C rate A
rate B