1.5 EN54 Optional Features with Requirements
In addition to the mandatory requirements of EN54 Part 2, the Control and Indicating Equipment (CIE) supports
the following optional features with requirements: -
Section 7.8
Outputs to Fire Alarm Devices.
The C.I.E has provision for connection to Fire Alarm Devices. It is possible to Silence
and Resound the alarms at Level 2. Refer to the User Manual for further information.
Refer to Sections 3.3.20 and 3.3.21 for information on output programming.
Section 7.9
Outputs to Fire Routing Equipment.
The C.I.E has provision to signal the fire condition to a remote receiving station such
as the fire brigade office. Requires installation of a routing interface card. Refer to
Sections 2.4.1/2.4.5, 2.5.12/2.5.13, 3.3.20, and 3.3.21 for further information.
Section 7.10
Outputs to Fire Protection Equipment.
The C.I.E has provision to signal the fire condition to a remote receiving station such
as the fire brigade office. Requires installation of a routing interface card. Refer to
Sections 2.4.1, 2.5.12, 3.3.20, and 3.3.21 for further information.
Section 7.11
Delays to Outputs.
The C.I.E has provision for Output and Investigation Delays. Refer to Sections 3.3.20
& 3.3.21 for further information
Section 7.12
Coincidence Detection.
The C.I.E has provision for Coincidence Detection. Refer to Section 3.3.20 for further
information. Types B and C are supported.
Section 7.13
Alarm Counter.
The C.I.E has provision to record the number of times that the fire alarm condition is
entered. Refer to the User Manual for further information.
Section 8.3
Fault Signals from Points.
The C.I.E is able to receive and process fault signals from points. These are indicated
on a per zone basis. Refer to the User Manual for further information.
Section 8.9
Outputs to Fault Routing Equipment.
The C.I.E has provision to signal the fault condition to a remote receiving station such
as the service centre office. Requires installation of a routing interface card. Refer to
Sections 2.4.1/2.4.5, 2.5.12/2.5.13, 3.3.20, and 3.3.21 for further information.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Advanced MxPro 5 Mx-5400 and is the answer not in the manual?

Advanced MxPro 5 Mx-5400 Specifications

General IconGeneral
BrandAdvanced
ModelMxPro 5 Mx-5400
CategoryFire Alarms
LanguageEnglish

Related product manuals