Newswift 90-180 Motorised Antenna 26
4.53 F53: WOODED AREA DATA ERROR
An error within the antenna wooded data area has been detected. The antenna wooded
areas will revert back to the factory default values. (All off.) If any wooded areas have been
set to avoid the antenna mechanically hitting an obstruction these will have to be re-
programmed.
4.54 F54: CALIBRATION AREA DATA ERROR
An error within the calibration data area has been detected. The antenna calibration data will
revert back to the factory default values. The antenna will require re-calibration.
4.55 F55: FPGA COMPATIBILITY ERROR
The version of FPGA code does not match the version required by the DCU software.
Contact Advent Communications customer support for advice.
4.56 F56: EXTERNAL FLASH ERASING/WRITING ERROR
An error erasing or writing to the flash memory external to the DCU processor has been
detected. Contact Advent Communications customer support for advice.
4.57 REMOTE CONTROL
The serial interface is standard RS485.
4.58 SERIAL INTERFACE: SOFTWARE PROTO-COL
The remote address and serial baud rate to the DCU4000 is fixed, and reset every power up.
Remote Address : 180
Baud rate : 9600