22 microAeth
®
MA Series MA200, MA300, MA350 Operating Manual microAeth
®
MA Series MA200, MA300, MA350 Operating Manual 23
AethLabsAethLabs
3.4. Consumables
MA200 Filter Tape Cartridge
The lter tape cartridges are custom designed for use in the microAeth® MA200. The lter tape cartridges
have PTFE lter material for collecting a 3 mm sample spot. Cartridges each contain 15 sampling locations.
MA300 / MA350 Filter Tape Cartridge
The lter tape cartridges are custom designed for use in the microAeth® MA300 and MA350. The lter tape
cartridges have PTFE lter material for collecting a 3 mm sample spot. Cartridges each contain 85 sampling
locations.
3.5. Accessories
microCyclone™ PM2.5 Size-selective inlet
The microCyclone is a miniature PM2.5 size-selective inlet for the microAeth. This sharp-cut cyclone has a
size cut of 2.5 micron at 50 ml/min and 1.6 micron at 100 ml/min.
microAeth MA Series Flow Calibration Kit
The microAeth MA Series Flow Calibration Kit comes with all of the components necessary to reliably perform
a ow calibration of the microAeth® MA Series instruments. This kit includes a custom designed external
mass owmeter and all necessary tubing, connectors, and cables to perform the simple and fully automated
ow calibration. The only way to perform a ow calibration on the MA Series instruments is to use the
AethLabs MA Series Flow Calibration Kit.
Portable Aerosol Dryer
A small, portable, passive naon / dessicant aerosol dryer. Dessicant life of 500 liters before recharge or
replacement.
Serial to bare leads cable
This cable allows the microAeth MA Series instruments to send and receive 3.3v TTL serial data from the
4-pin serial port to and from other devices. This cable is not included.
MA350 Sealed connector to bare leads cable
This cable allows the microAeth MA350 to send and receive 3.3v TTL serial data to and from other devices.
This cable also allows the MA350 to be powered from an external source. This cable is not included.
3.6. Replacement Parts
microAeth MA Series Flow Calibration Kit Communication cable
This cable allows the microAeth MA Series instruments to communicate with the custom designed external
mass owmeter in the microAeth MA Series Flow Calibration Kit. This cable is included in the microAeth MA
Series Flow Calibration Kit.
microAeth MA Series Flow Calibration Kit Inlet lter
This low backpressure inline disc lter is used on the inlet of the external owmeter of the microAeth MA
Series Flow Calibration Kit to keep the external owmeter clean and to keep the microAeth sampling lter
clean during ow calibration. An inline lter isn't required but is recommended especially if a ow calibration
is being completed outdoors or in a dirty environment.
Serial to USB converter cable
This cable allows the microAeth MA Series instruments to send and receive serial data from the 4-pin serial
port to the USB port of a computer. This cable is also used to upgrade the rmware of microAeth MA Series
instruments. This cable is included with all MA Series instruments.
MA350 Sealed connector to DC barrel jack and serial port cable
This cable converts the microAeth MA350 sealed connector port to a DC barrel jack port and a 4-pin serial
port. This cable is included with the MA350.