Hardkey and Softkey Reference ESG Family Signal Generators
Sweep/List
4-100 User’s Guide
Freq&Ampl
Press this softkey to set the signal generator to sweep both frequency
and amplitude data. Both the frequency and the amplitude lists must
have the same number of points or they must have only one point. If a
list has only one point, then that point is used for each of the other list’s
points.
Softkey Location:
Sweep/List > Sweep > Freq&Ampl
Freq Start
Press this softkey to set the frequency of the first point in the sweep.
You can set the value anywhere in the range of the signal generator’s
specified output frequency. Press
Freq Start and frequency becomes the
active function for the first point in the sweep. To enter the value, rotate
the front panel knob until the desired value is displayed, use the up and
down arrow keys, or enter the value using the numeric keypad and
press the
GHz, MHz, kHz, or Hz terminator softkey.
Default Value: Maximum specified frequency
Softkey Location:
Sweep/List > Configure Step Sweep > Freq Start
Freq Stop
Press this softkey to set the frequency of the last point in the sweep.
You can set the value anywhere in the range of the signal generator’s
specified output frequency. Press
Freq Stop and frequency becomes the
active function for the last point in the sweep. To enter the value, rotate
the front panel knob until the desired value is displayed, use the up and
down arrow keys, or enter the value using the numeric keypad and
press the
GHz, MHz, kHz, or Hz terminator softkey.
Default Value: Maximum specified frequency
Softkey Location:
Sweep/List > Configure Step Sweep > Freq Stop
Goto Bottom Row
Press this softkey to move the selection bar to the bottom row of list
sweep points when you are in the Goto Row menu that is accessed from
the Configure List Sweep menu. If you are in the Goto Row menu that
is accessed from the Load/Store menu, the selection bar moves to the
bottom row of the catalog of list files.
Softkey Location:
Sweep/List > Configure List Sweep > Goto Row >
Goto Bottom Row
Or: Sweep/List > Configure List Sweep > Load/Store > Goto Row >
Goto Bottom Row

Other manuals for Agilent Technologies E4430B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies E4430B and is the answer not in the manual?

Agilent Technologies E4430B Specifications

General IconGeneral
BrandAgilent Technologies
ModelE4430B
CategoryPortable Generator
LanguageEnglish

Related product manuals