Agilent Technologies
Agilent
U8001A/U8002A
Single Output
DC Power Supplies
User’s and Service Guide

Questions and Answers:

Agilent Technologies U8001A Specifications

General IconGeneral
BrandAgilent Technologies
ModelU8001A
CategoryPower Supply
LanguageEnglish

Summary

Notices

Warranty Information

Warranty terms and conditions for the document content.

Technology Licenses

License terms for the hardware and software described in this manual.

Restricted Rights Legend

Government rights for software and technical data, as per federal regulations.

Safety Notices

Defines CAUTION and WARNING messages for safe instrument operation.

Safety Symbols

Electrical and Terminal Symbols

Symbols for current types, ground, protective, and chassis terminals.

Power, Protection, and Hazard Symbols

Symbols for power status, insulation, electric shock, danger, and hot surfaces.

Control Symbols

Symbols indicating bi-stable push control positions.

General Safety Information

WARNING Precautions

General safety precautions: Do not use damaged devices; observe markings; avoid flammables; no unauthorized modifications; use provided adapter.

CAUTION Precautions

General safety precautions: Use provided cables; qualified personnel for service.

Environment Conditions

Environment Requirements Table

Specifies operating temperature, humidity, storage, and altitude for the instrument.

Safety and EMC Compliance

Lists relevant safety and EMC standards the product complies with.

Regulatory Markings

European and Canadian Markings

CE mark for EU directives and ICES/NMB-001 for Canadian ISM devices.

North American and Australian Markings

CSA mark for Canada, C-tick for Australia, and WEEE for electronic waste.

Declaration of Conformity

Manufacturer and Product Details

Identifies manufacturer and product name, models, and options.

European Directive Compliance

Declares compliance with Low Voltage and EMC Directives.

Conforming Standards

Lists specific EMC and Safety standards the product meets.

Declaration Details

Provides date of declaration and Quality Manager information.

Product Regulations

EMC and Safety Standards List

Details EMC and Safety standards with performance criteria and notes.

Performance Criteria Definitions

Definitions for performance criteria A, B, C, D, and N/A.

Regulatory Notes

Specific regulatory information for Canada and Australia/New Zealand.

In This Guide...

Quick Start Overview

Chapter 1 covers initial setup, output checks, and rack-mounting.

General Information Overview

Chapter 2 explains instrument description, panel layouts, and installation.

Operations and Features Overview

Chapter 3 details operational features and protection mechanisms.

Specifications and Characteristics Overview

Chapter 4 lists performance and supplemental characteristics.

Service Guide Overview

Chapter 5 provides warranty, troubleshooting, and calibration procedures.

1 Quick Start

Preliminary Checkout

Steps to validate the power supply readiness: check items, connect power.

Output Checkout

Procedures to verify rated outputs and front panel response.

Troubleshooting Power-On Issues

Guidance for issues when the power supply does not turn on.

Rack-Mounting Instructions

Instructions for mounting the instrument in a 19-inch rack cabinet.

2 General Information

Front Panel at a Glance

Overview of the front panel controls, indicators, and their functions.

Rear Panel at a Glance

Overview of the rear panel connectors and components.

Display Annunciators

Explanation of the meaning and function of each display annunciator.

Instrument Description

General description of Agilent U8001A/U8002A power supplies and their features.

Installation and Initial Inspection

Procedures for receiving, inspecting, and preparing the instrument for installation.

Cooling and Location

Guidelines for proper cooling and placement of the power supply.

Output Connections and Voltage Drops

Instructions for connecting outputs and managing voltage drops for optimal performance.

3 Operations and Features

Constant Voltage Operation

Step-by-step procedure for performing constant voltage (CV) operation.

Constant Current Operation

Step-by-step procedure for performing constant current (CC) operation.

Memory Operations

Instructions for storing and recalling operating states using memory locations.

Programming Over Voltage Protection

How to set the OVP trip level, enable, disable, and clear OVP conditions.

Programming Over Current Protection

How to set the OCP trip level, enable, disable, and clear OCP conditions.

Keylock Operation

Enables and disables the front panel lock function for settings security.

Backlight Operation

Instructions for turning the LCD backlight on and off.

System Related Operations

Procedures for resetting to factory defaults and understanding power-on self-test.

4 Specifications and Characteristics

Performance Specifications

Table detailing electrical parameters like output ratings, regulation, noise, and accuracy.

Supplemental Characteristics

Details temperature coefficient, voltage overshoot, programming speed, and protection features.

AC Power Input Specifications

Specifies input voltage options and fuse requirements.

Physical Specifications

Provides dimensions and weight of the power supply models.

5 Service Guide

Equipment Warranty

Information on warranty terms, extended service contracts, and obtaining repair service.

Replacement Parts

List of replaceable parts with part numbers and descriptions for ordering.

Troubleshooting

Checklist for common failures and troubleshooting steps, including unit inoperability.

Line Voltage Conversion

Procedure for changing the line voltage setting and replacing the fuse.

CV Verification Procedures

Tests for verifying Constant Voltage programming and readback accuracy.

CC Verification Procedures

Tests for verifying Constant Current programming and readback accuracy.

Voltage Calibration

Steps for calibrating the power supply at low, middle, and high voltage points.

Current Calibration

Steps for calibrating the power supply at low, middle, and high current points.

Appendix

List of Error Codes

Table of operation and calibration error codes with their interpretations.