Period Types:
Period Types allow you to change the access parameters based on a time schedule.  The TL-2000 has 5 different periods 
that can be scheduled, Group A, B, C, D, and Door Panel.  A period type is a 7 day week schedule, with 1 time zone, 2 time 
zones, or a combination of both.  To start, click on Period Types from the Parameters tab.
Click on Parameters
Click on Period Types
A
B
C
E
F
G
H
I
A) Group A, B, C, D, allows you to select 
up to four different groups, with each group 
having its own parameters for door entry 
controls.
B) Door Panel, allows you to determine 
what occurs at the door panel during the 
different periods. (see next page)
C) Keypad Codes, opens a 2
nd
window 
that allows you to enter 4 different codes 
for the specified period.  When the codes 
are entered during the specified period, 
Relay 1 will be activated.
D) Name, allows you to name the specific 
periods.
E) Calls Inside of Periods 1 and 2, will 
determine what the panel does during the 
specified periods when the bell button is 
pressed after locating a tenant.  Calls will 
allow the panel to call a tenant.  Activates 
Relay 1 will activate relay 1 instead of 
calling the tenant.  Activates Relay 2 will 
activate relay 2 instead of calling the 
tenant.  Activates Relays 1 and 2 will 
activate relays 1 and 2.  Activates 
Relay(s) of Resident will activate the relay 
associated with the tenant.  Security 
Delay triggers the associated relay after a 
specified timeframe to give the impression 
that the entrance was monitored before 
giving access to building. (max 60 sec)
F) Call Outside of Periods 1 and 2, will 
determine what the panel does outside of 
the specified period.  Calls will allow the 
panel to call the tenant.  Plays Message 2
will play pre-recorded message 2 rather 
than call the tenant.  The default message 
2 is “Your correspondent cannot be 
reached at this time, please try again 
later”.  Calls Caretaker calls the pre-
assigned number rather than the tenant.
G) Bank Holidays will refer to isolated 
dates that should ignore the specified 
periods.  Enter the month and day 
numerically.
H, Period 1, Period 2.  Enter the hour and 
minute for each day for the start and end of 
the specified period.  Put time in the 24 
hour format.  If all times are the same as 
Monday, simply click on the Copy Monday
button to auto-populate the remaining 
days.
I) Holidays, allows you to enter a start 
date and end date if sequential days need 
to ignore the specified periods. Enter as 
month/day/year.
D