EasyManua.ls Logo

Air Torque AT551U - Page 35

Default Icon
53 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EB AT-RP-4GU EN 9-11
Service
Holding the stop screw (02) in position, tighten the stop
adjustment nut (04) to lock the stop screw (02).
Î Refer to the section 15.2 ‘Tightening torques‘. (Table 15.3)
Open position
With the actuator in open position (90° position), screw or
unscrew the left stop screw (02) 1 turn at a time until the
desired stop position is achieved.
Holding the stop screw (02) in position, tighten the stop
adjustment nut (04) to lock the stop screw (02).
Î Refer to the section 15.2 ‘Tightening torques‘. (Table 15.3)
Regulate the extra travel stop adjustment, if any.
Î Refer to the data sheet [T.D.S. 2.1.5.1.1] for extra travel
stop adjustment.
9.5.7 Mounting the actuator over the valve
Refer to the section 5.3 ‘Mounting the actuator over the valve‘.