Heatless Regenerative Desiccant Air Dryer | AHLD Series
13
INSTALLATION
Pre-requisites for Installation
To ensure a safe and smooth installation, we recommend you
go through the steps indicated below:
Make sure that all personnel involved have read this
operation manual thoroughly. If you have any questions,
please contact your Aircel represenative or the factory
and we will be glad to assist you. If you need help with
the commissioning, we will be glad to schedule an
Aircel factory service technician to visit your site and
commission the dryer for a nominal fee.
Have extra copies of the operation manual.
Special care must be taken while transporting the unit to
the installation site.
Dryer must not be moved or lifted by the attached piping.
Location
Careful consideration should be given to the location of
the dryer in order to assure optimum results. Ensure that
the load bearing weight of the floor is adequate for the
weight of the dryer.
The dryer should be located in an open area and a level
ground. Dryer should be bolted to the floor to eliminate
vibrations.
The ambient temperature should be between 40°F and
100°F. Low temperature could affect the dryer process
and result in high outlet dew point.
In conditions where the ambient drops below freezing,
Aircel recommends the use of heat trace on any
coalescing filter sumps and drain lines and the use of
heated type draings.
Dryer and accompanying filters should be installed with
at least 2-5 feet clearance from the adjoining walls to
provide easy access for routine maintenance.
Drain
Valve
Air or Water
Cooled
Condenser
Air
Compressor
Drain
Valve
Dry Air
to Plant
Drain
Valve
Drain
Valve
After Filter
Pre-Filter
Separator
TYPICAL INSTALLATION DIAGRAM