USING YOUR WIRED THERMOSTAT
Adjusting the temperature
Operation Mode*
On/O. Press to switch On/O the zone.
Temperature Control. The temperature displayed on the screen is the
current set point temperature. You can easily adjust the set point on your
wired Thermostat.
Press the set point temperature to switch between heating and cooling set
points. Press Up or Down to manually adjust by increments of 1ºF (0.5ºC).
The permitted temperature range is:
• Heating mode: 59º F – 84º F/ 15º C - 28º C.
• Cooling mode: 64º F – 86º F/ 17º C - 30º C.
If you are using Auto mode, note that there is a minimum dierence allowed
between heating and cooling set point temperatures. The system will
prevent you from setting a temperature within the protection range.
Cool. In this mode the air-conditioning unit will start a cooling cycle any
time that any zone is in cool demand (T
Heat. Enables the heating cycle whenever a zone is in heat demand
(T
Auto. The Auto mode allows automatic switching between cool and heat,
depending on the global demand.
Dry. In this mode the air-conditioning unit will start a dehumidication
cooling cycle any time that any zone is under demand (T
72º
*Only available to the Main thermostat.
To change Operation Mode
From the Home Screen:
- Press icon mode.
-Select your Operation
Mode:
• Cool
• Heat
• Auto
• Dry
• Emergency Heat*
*This option is only visible if
it has been congured
Dry
Dry mode decreases
humidity in the
room by entering the
dehumidication cooling
cycle.
Set-Point
< T ).
room
Set-Point
< T ).
room
Set-Point
> T ).
room
Emergency heat. This mode activates the Auxiliary Heat to provide heated
air in case of a mechanical failure in the system.
*Note: This mode is only visible when the installation includes an auxiliary heating device.