2. Put the Z-Wave controller into inclusion mode. Refer to the controller documentation for more information.
3. Press and hold the DOWN button on the thermostat to begin inclusion mode. Release the button when the RADIO
icon lights up.
4. When the RADIO icon becomes solid, the thermostat has been included.
5. Login to your online account (www.alarm. com/login) to sync the thermostat with the Alarm.com system, or contact an
Alarm.com professional for installation setup.
CONFIGURE THE SYSTEM
The thermostat configuration will be done on your online account. Here you can configure the parameters of the system,
such as: Heat Pump or Normal, number of heat and cool stages, heating fuel, calibration temperature, and configurable
terminal (Z). In your online account, you will have to enter the thermostat configuration. Refer to page 7 for the
appropriate diagrams when you set up the thermostat.
While the default settings will be sufficient in most cases, you also have the option to change advanced configuration
settings, such as: Swing, Differential, Recovery Settings, Fan Circulation Period and Duty Cycle, Maximum Set Points,
Minimum Set Points and Thermostat Lock.
The thermostat can be configured locally for the most common configurations. Please see Page 12 for instructions.
WARNING: Use caution when changing advanced configuration settings. These configuration settings should only be
changed by those familiar with heating and cooling systems’ parameters. Contact a local HVAC professional for help.
CHECK THE SYSTEM
WARNING: Do not test the AC during cold weather or heat during hot weather. Wait for mild weather to fully test the
system.
To Check Heating
1. Press the MODE button to select HEAT mode.
2. Press the UP button to raise the set point above room temperature.
3. Wait 5 minutes for the system to turn on.
4. After verifying the heating system is working, return the set point to the desired temperature.
To Check Cooling
1. Press the MODE button to select COOL mode.
2. Press the DOWN button to lower the set point below room temperature.
https://answers.alarm.com/Installation_and_Troubleshooting/Thermostats/Z-Wave_Thermostats/Alarm.com_Smart_Thermostat_(ADC-T2000)/Alarm.com_Smart_Thermostat_(ADC-T2000)_Installation_Guide
Updated: Sun, 15 Oct 2017 23:38:59 GMT
Powered by
11

Other manuals for Alarm.Com ADC-T2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alarm.Com ADC-T2000 and is the answer not in the manual?

Alarm.Com ADC-T2000 Specifications

General IconGeneral
BrandAlarm.Com
ModelADC-T2000
CategoryThermostat
LanguageEnglish

Related product manuals