The Scanner has following receiving data
Frequency Band
Sensitivity (Nominal) 12 dB SINAD
25.000 - 27.995
0.4
µV
28.000 - 69.9950
0.2
µV
70.0000 - 87.2950
0.2 uV
108.0000 - 136.9916
0.4 uV
137.0000 - 147.9950
0.2 uV
148.0000 - 174.0000
0.2 uV
406.0000 - 512.0000
0.3 uV
806.0000 - 960.0000
0.4uV
Frequency Band
Hum and Noise (Nominal)
25.000 - 27.995
48 dB
28.000 - 87.2950
43 dB
108.0000 - 136.9916
48 dB
137.0000 174.0000
43 dB
400.0000 - 512.0000
42 dB
806.000 - 960.0000
44 dB
Frequency Band
Close Call Sensitivity (Nominal)
25.000 - 87.2950
-54 dB
108.0000 - 136.9916
-61 dB
137.0000 - 174.0000
-63 dB
406.0000 - 512.0000
-65 dB
806.0000 - 960.0000
-55 dB