Alarm Data Value/Meaning
AID Type (continued) SVAC-shelf-slot
WR-shelf-slot-{SIG, THRU, DROPOUT,
ADDIN{1-8}, MESHOUT{1-3}}
WTOCM-shelf-slot-IN{1-4}
Effect on Service NSA
Alarm Entity Type EQPT
Description Manually caused abnormal condition - port in
maintenance
Corrective Action Proceed to “MAN” (p. 2-177).
3of3
Alarm Data Value/Meaning
Severity Level MN
AID Type LINEREFSYS-shelf-slot-{0-3}
Effect on Service NSA
Alarm Entity Type LINEREF
Description A logical removal was performed on a timing
reference.
Corrective Action Proceed to “MAN” (p. 2-177).
MANRESET
Alarm Data Value/Meaning
Severity Level Not alarmed
Alarm and condition details MAN
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1-120