EasyManua.ls Logo

Alcatel-Lucent 1830 PSS-4 - Manswtimref; Manswtoint

Alcatel-Lucent 1830 PSS-4
722 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Alarm Data Value/Meaning
Alarm Entity Type EQPT
Description Card Manual Reset
Corrective Action Proceed to “MANRESET” (p. 2-181).
MANSWTIMREF
Alarm Data Value/Meaning
Severity Level Not alarmed
AID Type LINEREFSYS-shelf-slot-{0-3}
Effect on Service NSA
Alarm Entity Type LINEREF
Description Timing selection was switched by a manual
command to a timing reference.
Corrective Action Proceed to “MANSWTIMREF (p. 2-182).
MANSWTOINT
Alarm Data Value/Meaning
Severity Level Not alarmed
AID Type SYNC-shelf-slot-0
Effect on Service NSA
Alarm Entity Type SYNC
Description A manual switch to Internal Timing (forced
Free-Running mode) has occurred
Corrective Action Proceed to “MANSWTOINT” (p. 2-182).
Alarm and condition details MANRESET
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1-122
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011

Table of Contents

Related product manuals