Alarm Data Value/Meaning
Alarm Entity Type OTS
Description Amplifier gain tilt adjustments suspended
Corrective Action Proceed to “PWRTILTSUSP” (p. 2-276).
RAMANSUSP (Raman Suppress - Line)
Alarm Data Value/Meaning
Severity Level MJ
AID Type AHPHG-shelf-slot-Line
AHPLG-shelf-slot-Line
ALPHG-shelf-slot-Line
AM2017B-shelf-slot-Line
AM2125A-shelf-slot-LineIn
AM2125B-shelf-slot-LineIn
AM2325B-shelf-slot-Line
Effect on Service SA
Alarm Entity Type OTS
Description Raman Suppress - Line
Corrective Action Proceed to “RAMANSUP” (p. 2-276).
RCVROPTPROG
Alarm Data Value/Meaning
Severity Level MN
Alarm and condition details PWRTILTSUSP
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1