EasyManua.ls Logo

Alcatel-Lucent 1830 PSS-4 - Sltmsig; Ssf

Alcatel-Lucent 1830 PSS-4
722 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Alarm Data Value/Meaning
AID Type (continued) SVAC-shelf-slot
WR-shelf-slot
WTOCM-shelf-slot
Effect on Service SA
Alarm Entity Type EQPT
Description Software version mismatch
Corrective Action Proceed to “SFMISMATCH” (p. 2-292).
SLTMSIG
Alarm Data Value/Meaning
Severity Level MN
AID Type LINEREFSYS-shelf-slot-{0-3}
Effect on Service SA
Alarm Entity Type LINEREF
Description Timing reference frequency has moved off the
required accuracy limits (not Protected or
Protection not Available)
Corrective Action Proceed to SLTMSIG” (p. 2-293).
SSF
Alarm Data Value/Meaning
Severity Level NR
Alarm and condition details SFMISMATCH
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1-176
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011

Table of Contents

Related product manuals