OPRLOSSHIGH
Description
Alarm Data Value/Meaning
Severity Level Not alarmed
AID Type A2325A-shelf-slot-Dcm
AHPHG-shelf-slot-Dcm
AHPLG-shelf-slot-Dcm
ALPHG-shelf-slot-Dcm
ALPFGT-shelf-slot-Line
AM2017B-shelf-slot-Dcm
AM2125A-shelf-slot-Dcm
AM2125B-shelf-slot-Dcm
AM2325B-shelf-slot-Dcm
Effect on Service NSA
Alarm Entity Type OTS
Description Out of Operational Range – Loss Too High
between DCM Ports of LD
Corrective Action Proceed to “OPRPWRHIGH” (p. 2-233).
OPRLOSSLOW
Alarm Data Value/Meaning
Severity Level Not alarmed
AID Type A2325A-shelf-slot-Dcm
AHPHG-shelf-slot-Dcm
AHPLG-shelf-slot-Dcm
ALPHG-shelf-slot-Dcm
AM2017B-shelf-slot-Dcm
AM2325B-shelf-slot-Dcm
Effect on Service NSA
Alarm Entity Type OTS
Description Out Of Operational Range - Loss Too Low
Alarm and condition details OPRLOSSHIGH
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1-148
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011