Alarm Data Value/Meaning
Effect on Service NSA
Alarm Entity Type 11DPE12: 1GbE
11QPA4: 10GbE, FC800, FC1200,
OC192/STM64
11STAR1: 10GbE, FC1200, OC192/STM64
11STMM10: 1GbE, CBR2G5, FC100, FC200,
FC400, OC3/STM1, OC12/STM4,
OC48/STM16, OTU1
11STGE12: 1GbE
4DPA2: 1GbE, OC48/STM16
4DPA4: 1GbE, CBRAR, FC100, FC200,
OC3/STM1, OC12/STM4, OC48/STM16
OPS: OCH
Description Manual switch to protection
Corrective Action Proceed to “MANWKSWPR” (p. 2-184).
MISMATCH
Description
Card mismatch
Alarm Data Value/Meaning
Severity Level CR
Alarm and condition details MANWKSWPR
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1-124
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011