MISMATCH (Card Mismatch)
The Card Mismatch alarm indicates that the card inserted into the affected slot is of a
different type than that which was provisioned. This could occur when there is a card type
mismatch.
Severity Critical
Service affecting? Yes
Applicability 112SA1L, 112SCX10, 112SX10L, 11DPE12E, 11DPM12,
11STAR1, 11STMM10, 11STGE12, 43SCX4, 43STA1P, 43STX4,
43STX4P, 4DPA2, 4DPA4, ALPHG, AHPHG, AHPLG, ALPFGT,
AM2017B, AM2125A, AM2125B, AM2318A, DCM, CWR,
ITLB, ITLU, MESH4, MVAC, OPS, OSCT, RA2P, SFC, SFD44,
SFD44B, SVAC, WR, WTOCM
Corrective Action
NOTICE
Service-disruption hazard
A cold reset, reseat, or replacement of a card is service impacting if the card is currently
carrying services. To determine if any services are currently carried over a card, perform
the procedure “Reseating a Card” (p. 3-19).
If
there are services currently carried over the card, it may be best to wait for a
maintenance window before resetting, replacing, or reseating the card.
At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
1
Display the provisioned card type:
CLI show slot shelf slot
WEBUI In the Equipment Tree, select the desired card slot.
On the Details tab, view the value in the Present/Provisioned field.
...................................................................................................................................................................................................
2
Verify from the network plan what type of card is supposed to be in that slot.
If... Then...
it is a frequency dependent card (SFC or SFD) ensure the correct frequency.
Trouble-clearing procedures
MISMATCH
MISMATCH (Card Mismatch)
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
2-186
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011