3
Remove the fiber from the port where the LOS was raised and measure the optical power.
If the optical power is below the threshold level provisioned by the Photonic Manager for
the type of port, then using standard optical fiber jumper cleaning procedure, clean the
fiber, and measure the power again. If the optical power is within the required limits,
clean the receive connector on the card. If the RCVROPTPROG condition is still present
more than 10 minutes after the LOS clears, the problem may be with the card.
...................................................................................................................................................................................................
4
Perform a warm reset of the card.
CLI config card card type shelf slot reset warm
WEBUI Select the card, click the Reboot tab, select Warm Reboot >Submit.
...................................................................................................................................................................................................
5
Perform a cold reset of the card.
CLI config card card_type shelf slot reset cold
WEBUI Select the card, click the Reboot tab, select Cold Reboot >Submit.
Note: Refer to Caution at the beginning of this procedure.
...................................................................................................................................................................................................
6
Reseat the card. Refer to “Reseating a Card” (p. 3-19).
...................................................................................................................................................................................................
7
Replace the card. Refer to “Replacing System Components” (p. 3-20).
RDI
RDI (Remote Defect Indication)
The OT port has detected a RDI at the MEP layer. A MEP detects RDI when it receives a
CCM frame with the RDI field set.
Severity Major
Trouble-clearing procedures
RCVROPTPROG
RCVROPTPROG (Receiver Optimization in Progress)
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
2-279
E ND OF STEPS
...................................................................................................................................................................................................